5
3062347_0309
Safety instructions / Standards and regulations
Standards and regulations
Category:
II2ELL3P<DE> and
II2H3P<AT>
NOx class:
5
Efficiency:
*** star rating according
to 92/42/CEE) for
balanced flue operation
Flue types:
CGG-2:
C12x, C32x, C42x, C52, B32
CGU-2:
B11BS
Operating mode:
open / balanced flue
To be connected to: chimney, flue chimney /
balanced flue system
- Obtain the permission of your mains gas supplier
and all relevant authorities prior to the installation of
Wolf gas fired combi boilers.
- Open flue gas fired boilers must only be installed
in a room that complies with the appropriate
ventilation requirements.
The gas fired boiler meets with the following regulations
EC Directives
- 2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 90/396/EEC Gas user equipment
- 92/42/EEC Efficiency directive
DIN / EN Standards
- EN 297; EN298; EN 483; EN 625;
EN 55014-2; EN 60335-1; EN 60335-2-102;
EN 60529; EN 61000-3-2; EN 61000-4-3
The following regulations, rules and guidelines must
be observed during installation:
-
Boiler room guidelines or Building Regulations
relating to the construction and installation of
central boiler rooms and fuel storage facilities
- Technical regulations for gas and DHW installations
DVGW-TRGI 1996 and TRF 1996
(in the currently applicable form)
DIN / EN Standards
- EN 437
Test gases; test pressures;
appliance categories
- DIN EN 1283
Procedure for calculating the
standard heating load
- DIN EN 12828 Heating systems in buildings
- DIN EN 1717
Protection of DHW against
contaminations in DHW
installations
- DIN EN 50156-1 (VDE 0116 part 1)
Electrical equipment for
combustion systems
- On site regulations from building and industry
regulatory agencies (mainly covered by the emission
test switch)
- On site regulations from the gas supply utility
Summary of Contents for CGG-2-18
Page 64: ...64 3062347_0309 Notes ...