46
3064298_201507
26. Display module / programming unit
installation
The BM-2 (programming unit) communicates with the split
air/water heat pump and all connected extension modules
via eBus.
Specification:
• Colour display 3.5", 4 function buttons, 1 rotary selector
with push-button function
• Micro SD card slot for software update
• Central programming unit with weather-compensated
flow temperature control
• Time program for heating, DHW and DHW circulation
The AM serves as a display and programming unit for the
split air/water heat pump. Parameters and values specific
to the split air/water heat pump can be programmed and
displayed.
Specification:
• LCD screen 3"
• 4 quick start keys
• 1 rotary selector with push-button function
Please note:
• Use when BM2 is used as a remote control or
in a cascade circuit
• AM is always in the heating appliance
AM
BM-2
Operating mode
Heating mode
HP status
ON
Status
2
1
3
14:12
20.01.13
1.5
bar
25.2
°C
1x
Boiler temperature
Heating appliance
HTG
Pressure
Operation
An AM display module is required for operating the split air/water heat pump. A BM-2 programming unit
can also be connected via eBus for other operating and display functions.
Plug the AM display module into the slot above the ON/OFF switch (Wolf logo).
Switch on power supply / MCB
and switch ON/OFF switch to ON.