24. Power supply to the outdoor module
Opening the casing
BWL-1S(B)-07
BWL-1S(B)-10
BWL-1S(B)-14
Mains
Connecting the outdoor module
BWL-1S(B)-07/230 V
BWL-1S(B)-10/400 V
BWL-1S(B)-14/400 V
3
Indoor module
terminal strip X1
Indoor module
terminal strip X1
15 16
14
13
BWL-1S(B)-10/230 V
BWL-1S(B)-14/230 V
*
AWO BUS
43 V (3x1.5 mm
2
screened, recommended)
Mains
5
*
Indoor module
terminal strip X1
14
13
Mains
3
*
* See "Specification" for fuse protection values
In terms of safe installation, the AWO BUS
connection (43 V / 12 V) is not low voltage and
must be routed together with the 230 V/400 V
cable.
Do not interchange wires L and N on the mains
connection. If wires L and N of the mains
connection are interchanged, the AWO BUS may
carry mains voltage, leading to appliance damage.
Only one BUS connection may be connected.
The wires of the AWO BUS connection between
the indoor and outdoor module must not be
interchanged.
AWO BUS
12 V (3x1.5 mm
2
screened,
recommended)
AWO BUS
12 V (3x1.5 mm
2
screened,
recommended)