64
Hotline: +49 2953 73-211
Fax: +49 2953 73-250
Wöhler DC 100
PRO
5. Menu - Volume measurements on gas lines
Figure 5.1: Cursor positioned at volume measurements
This function can determine the volume V
total
of a closed and airtight space
(e.g. in a tank, flask, or pipeline). A known sample volume V
sample
is taken from
the space (e.g. with a medical syringe or test pump) and the total volume
V
total
determined from the resulting pressure change. Boyle’s law returns the
following equation for the wanted volume V
total
:
with:
V
tot
wanted gas volume, max. 6000.0 l
V
sample
sample volume in l
∆
p
max
max. pressure difference in Pa caused by the
taking of the sample
p
act
absulute air pressure, entered manually under
the Setup menu (default 1013 hPa)
First of all, the investigated line, flask, or tank must be tightly sealed with a
suitable test plug. We recommend connecting a leak test set (art. no. 7217).
The DC 100
PRO
is connected to the gas line and switched ON.
5. Menu Volume measurements on gas lines
Equation. 5.1
V
tot
[1] = V
sample
[1] ·
(
p
act
[hPA]
∆
p
max
[hPA]
- 1
)
Temp. constant