The Options Tab
1.
Click the
Options
tab.
Figure 3–3: AMP1-16-M Manager Options Screen
2.
In the
Level Meters
area, click the drop downs to select the
Scale
,
Float
,
and
Bar
for your level meter display. Alternatively, you can click the
Meter
Scale Default
button to return to the default for that scale. The scale itself
won't change.
a.
Also in the
Level Meters
area, click the up or down arrows to select
the levels at which the colors between the top and middle segments
and the middle and lower segments.
b.
Click the up or down arrows to select the colors for each of the level
meter segments.
3.
Tone controls for the internal loudspeakers can be set in the front
panel Speaker Control Options Menu or in the Wohler AMP1-16-M
Manager PC program.
A certain amount of default EQ suitable for the speakers’ characteristic
frequency response is applied as the factory default. Tone control
settings have no effect on sound of headphones or line audio outputs.
4.
Selecting Flat gives the flattest measured response from the internal
speakers.
a.
Low Cut is provided for cases where unusually deep content
produces audible distortion.
b.
Bass and Treble are provided for custom tuning of the speaker
sound to fit your needs.
c.
Lowering Bass will unmask midrange band sounds, while increasing
Bass will make the sound “fatter”.