Page 56
7.
Loudness Window
: This may be set to
Momentary
,
Short
, or one of 22
values, ranging from one second to two hours.
8.
Monitoring Mode
:
a.
Manual
: Touch the Manual button to enable Manual Mode. This allows
you to measure the loudness of a specific program or segment of a
program, such as a commercial. In this mode, the
Start
and
Stop
button on the Loudness Meter screen can be manually used to begin
and end a loudness measurement interval. The reading for that
interval is then held on the Loudness Meter.
b.
Continuous
: Touch the
Continuous
button to enable Continuous
Mode. In this mode, loudness readings are continually made. The
Stop
button on the Loudness Meter screen is not active.
Note
: Further and more detailed descriptions of all of the above Loudness terms
may be found in the ITU-R BS.1770-3 loudness standard.
When you have finished making the settings click
Apply
to save them or click
Cancel
to discard them.
Phase Indicator Configuration Tab
The Phase Indicator Configuration tab
is as shown in Figure 4-9. It allows you to
select which channel pairs will receive a phase meter on the
Metering Screen
.
Generally, it is useful to monitor the relative phase of stereo pairs. However,
sometimes each channel of a pair is unrelated to each other. This can be because
the channels are used to convey two independent monophonic signals or that one
channel may be a Center channel and the other may be a Low Frequency Effects
channel. In these instances, the Phase Indicator would almost always indicate an
out of phase condition. Because this would be a needless distraction to the
operator, switches are provided on this tab to individually turn phase monitoring for
each channel pair on or off.
Select All
and
Reset All
buttons are also provided.
Figure 4–9: Phase Indicator Configuration Tab
When you have finished making the settings click
Apply
to save them or click