Page 25
Unit Configuration
Touching the
Unit Config
selection on the
Unit Settings
Menu proceeds to the
Unit Configuration Menu
. This menu is shown in Figure 2-17.
Figure 2-17: Unit Configuration Menu
Unit Configuration
Back
Grahics LCD Brightness
Video LCD Brightness
AES Termination
<
>
100
<
>
100
On
Video Info
<
>
Always On
Source Knob Selection
<
>
Source Select
The controls function as follows:
1.
Graphics LCD Brightness
: This setting adjusts the brightness of the right
display screen, which is used for meter displays and menus. Touch the left
pointing arrow to dim the brightness or touch the right pointing arrow to
increase the brightness.
2.
Video LCD Brightness
: This setting adjusts the brightness of the left
display screen, which is used for video. Touch the left pointing arrow to dim
the brightness or touch the right pointing arrow to increase the brightness.
3.
Video Info
: This setting determines if or how video information is displayed
when the video screen is selected by pressing the
Source
knob. The possible
selections are as follows:
a.
Always On
: The video information is always displayed.
b.
Off
: The video information is never displayed.
c.
5 Secs
: The video information is displayed for 5 seconds after the
video screen is selected and then it disappears.
d.
10 Secs
: The video information is displayed for 10 seconds after the
video screen is selected and then it disappears.
4.
AES termination
: AES signals should have one and only one termination.
This termination should physically be at the last destination of an AES coax
cable. If the iVAM2-2 is the last connection in a series of AES connections,
then its terminations should be turned on. A symptom of too many
terminations (or no termination) is that no signal appears to be present on
the AES input. Touch the
On - Off
switch to change the termination setting.
5.
Source Knob Selection
: This setting determines the function of the
Source
knob on the front panel. It may be set as follows, depending upon your
needs: