GMG-B Operation manual
Page 45 of 45
B0743
11.3 Control settings parameter sheet
Pump unit no.:
Menu item
Possible
setting
Setting
Factory
setting
P1
Selection between time and pulse mode
Time 001
Pulse 002
1
P2
Cycle time setting in hours in time mode
0
… 255
0
P3
Cycle time setting in minutes in time mode
0
… 59
2
P4
External machine pulse setting in pulse mode
1
… 9999
5
P5
Pump delivery switch-off via the number of
distributor pulses
On = 001
Off = 000
0
P6
Number of distributor pulses until pump delivery
switch-off
1
… 999
0
P7
Distributor monitoring
On = 001
Off = 000
0
P8
Delivery time setting in minutes
0
… 255
0
P9
Delivery time setting in seconds
0
… 59
1
P10 Selection of stirring function
Yes = 001
No = 000
0
P11
Off-duty time setting in hours between two stirring
processes
1
… 100
1
P21
Setting the monitoring time
for a distributor circulation in seconds
0 … 255
240