8.3 Inspection schedule
No.
Description
Interval
1
Check the presence and functionality of the
safety facilities
daily
2
Check the lube lines and connections for
mechanical integrity and leakage
monthly
3
Check the pump units and components for
mechanical integrity and leakage
weekly
4
Check the filling level of the pump unit
weekly
8.4 Repair
Changing the pump element:
Note!
Prior to pump element removal, the reservoir must be emptied
since otherwise lubricant may spill.
Note!
When removing the pump element, be careful to remove the
pressure spring and the delivery piston from the reservoir as
well. If these parts are left in the reservoir, the pump unit may
be damaged and, thus, fail.
Unscrew the pump element cautiously. Replace the old pump element by an exchange part.
When screwing down, be careful not to jam the connecting thread.
For other repairs, turn to WOERNER, please.
Spring