Wodaplug.com OLT CLI User Manual
www.wodaplug.com
53
PVID :1 DefaultPriority :0
Learning :enable AccFrameType :All
CfgSpeed :1000M CfgDuplex :full
WorkSpeed :10M WorkDuplex :half
CfgFlwCtrl :disable LinkStatus :down
IngressRateCtrlType:All IngressRateLimit:0
EgressRateLimit :0
------------------------------ End ------------------------------
4.3.8.15.
Configure Port’s Compulsive Shutdown Function
Command
Grammar
epon(ge1)#
shutdown
Function
Configure switch control module port’s compulsive shutdown
function. In an exceptional case, such as attached by virus or hacker
and can’t take any actions ASAP , the shutdown port function is
recommended .
4.3.8.16.
Remove Compulsive Shutdown Port
Command
Grammar
epon(ge1)#
no shutdown
Function
Remove switch control module port’s compulsive shutdown function.
In an exceptional case, such as attached by virus or hacker and can’t
take any actions ASAP , the shutdown port function is recommended .
4.3.8.17.
Configure Current Port Rate
Command
Grammar
epon(ge1)#
speed <
speed
>
Function
Configure switch control module port’s speed.Under fiber port
mode ,the port could only work at the speed of 1000Mbps;Under the
copper port mode ,the port can work at different speed and
available for auto-negotiation function configuration .
<
speed
>
10m: 10mbps