Wodaplug.com OLT CLI User Manual
www.wodaplug.com
17
1.Enquiry the current inband network management port’s network configuration:
epon(net)#address vi0
Interface vi0:
Ip address :192.168.1.100
Netmask :255.255.255.0
associated vlan :1
admin status :operational
Example 2:Configure inband management IP as 192.168.1.1 ,mask is 255.155.155.0
epon(net)#address vi0 192.168.1.1 255.255.255.0
Example 3:Configure outband management IP as 192.168.1.2 and mask is 255.255.255.0
epon(net)#address cpm0 192.168.1.2 255.255.255.0
4.3.3.2.
Configure NMS Port Gateway
Command
Grammar
epon(net)#
gateway
<ip-addr>
Function
Configure NMS port’s gateway.
Input command gateway to show the current gateway information.
<ip-addr>
Configure the appointed gateway address.
4.3.4.
OLT Management Mode
4.3.4.1.
Enter OLT Management Mode
Command
Grammar
epon#
olt
<slotid> <oltid>
Function
Enter OLT management mode to configure OLT,downplink and ONU .
just input “olt” could show the current online OLT .
<slotid>
olt pon module slot with value 0 .
<oltid>
Pon ID with valid value 1 and 2 .