The local power supply must be constructed according to IEC 364. To improve safety, the coffee machine should be
fitted with an FI 30 mA earth leakage current circuit breaker complying with EN 61008. Near the machine or about 30
cm below the counter top there should be a shockproof socket as a single-phase connection installed locally on the
rear or side wall of the counter substructure or a country-specific single-phase socket and, in the case of a 3-phase
connection, a 5-pin CEE / CEKON-socket according to EN 60309 or a country-specific multi-pin socket. The socket is
part of the customer‘s on-site installation. The mains cable must not come into contact with hot surfaces. If the mains
cable for this device is damaged then it must be replaced by our service personnel or a similarly qualified person, in
order to prevent hazards.
In order to avoid possible faults from arising on our screened data lines due to potential equalization currents
between the devices, an additional potential equalization unit should be planned for devices connected to the
vending system. (See EN 60309)