68
User Manual WMF 150 F
These specifi cations for the electrical connection and the standards quoted apply
for connecting the coffee machine in EU countries. It may be necessary to also read
additional country-specifi c regulations. Outside the EU countries acceptance of the
standards quoted is to be checked by the legal entity or natural person who wishes to use
the coffee machine.
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
To improve safety, the device should be fi tted with an FI 30 mA earth leakage current circuit breaker
complying with EN 61008. (Type B residual current circuit breakers provide reliable tripping even
if the fault current is smooth. This ensures a high level of safety.) Near the device or about 30 cm
below the counter top there should be a shockproof socket as a single-phase connection installed
locally on the rear or side wall of the counter substructure or a country-specifi c single-phase socket
and. The mains switch and plug top are part of the on-site installation. The mains cable must not
come into contact with hot surfaces. If the mains cable for this device is damaged then it must
be replaced by our service personnel or a similarly qualifi ed person, in order to prevent hazards.
The coffee machine may not be fi tted with a fi xed permanent mains connection if installed on a
transporting trolley (a mobile station).
Summary of Contents for 150 F
Page 70: ...70 User Manual WMF 150 F ...
Page 71: ...71 User Manual WMF 150 F ...