57
User Manual WMF 150 F
6.3 Errors without error message
Error pattern
Possible cause:
Action instructions
•
The machine is not
working.
The fuse in the fuse box has
been triggered. The group is
loaded too heavily.
Replace the fuse or reset it.
Connect the machine to a
separate group.
•
The brewing process
indicator illuminates,
but no water is going
into the fi lter.
The dry-boil protection has
been triggered.
Reset the dry-boil protection.
Refer to page 24. Safeguards;
dry-boil protection.
•
The descale indicator
illuminates.
The scale deposits in the
heating system exceed the set
limit.
Descale the machine. Refer to
chapter 5: Maintenance and
descaling.
•
The descale indicator
light remains on
after descaling the
machine.
The machine has not yet been
reset.
Press the program button for 6
seconds. The light will go out.
Refer to chapter 3.7 Resetting
the descaling indicator light.
•
Steam is coming
from the fi lter.
The machine was not descaled
when indicated by the descale
indicator light. The wrong
water setting has been applied.
Descale the machine. Refer to
chapter 5 Maintenance and
descaling.
Refer to chapter 3.4 Setting the
descaling indicator.
•
The coffee is too
strong.
Too much coffee has been
placed in the fi lter.
Reduce the amount of coffee.
•
The coffee is too
weak.
Not enough coffee has been
placed in the fi lter.
Increase the amount of coffee.
The water distributor is soiled,
so that the coffee is not being
completely drenched.
Unscrew the water distributor
and clean it.
•
The coffee is not hot
enough
There is no lid on the jug.
Use the lid.
•
The jug is too full or
is overfl owing.
The set quantity is too high.
Lower the quantity.
Refer to chapter 3.1 Setting the
amount of coffee.
•
Not enough coffee is
getting into the jug.
The set quantity is too low.
Increase the quantity.
Refer to chapter 3.1 Setting the
amount of coffee.
Summary of Contents for 150 F
Page 70: ...70 User Manual WMF 150 F ...
Page 71: ...71 User Manual WMF 150 F ...