Document specifications 

This  documentation  was  made  for  presenting  the  installation  and  configuration  steps  of  the 
WM-I2

®

 pulse counter and transmitter device.  

Document Version: 

REV 1.2 

Hardware Type/Version: 

WM-I2

®

 pulse counter modem  

Hardware Version: 

V 2.10 

Bootloader Version: 

V 1.80 

Firmware Version: 

V 2.04.05 

WM-I2 Term

®

 configuration  

software version: 

V 0.44 

Pages: 

26 

Status: 

Final 

Created: 

16-11-2020 

Last Modified: 

16-11-2020 

 

 

 

 
 
 
 
 

 

Summary of Contents for WM-I2

Page 1: ...User manual for WM I2 metering modem v1 2 ______________________________________________ 2020 11 16...

Page 2: ...the WM I2 pulse counter and transmitter device Document Version REV 1 2 Hardware Type Version WM I2 pulse counter modem Hardware Version V 2 10 Bootloader Version V 1 80 Firmware Version V 2 04 05 WM...

Page 3: ...is in stand by operation Then it wakes up at the pre defined intervals to transmit the collected consumption data through the NB IoT mobile network to a server IP address Therefore the collected and c...

Page 4: ...warning of a failure Battery capacity monitoring in case of low voltage detection it will notify about the necessity of battery exchange by transmitting the voltage level value Configuration The modem...

Page 5: ...pter 2 Connections 2 1 External view 2 2 External view bottom side The top cover of the modem s enclosure which provides a safe and dehumified lock by using the internal silicone ring inside of the co...

Page 6: ...e enclosure 4 Internal antenna connector U FL for SMA M connector 50 5 Special filled longlife battery Lithium Thyonyl Chloride 3 6V DC CR14250 type 6 SIM card slot for micro SIM 3FF type 7 Connection...

Page 7: ...ut Connection interface with cabling terminal block J11 which can be used for connection the pulse input of the meter for connecting cables of cut detection Pin nr Comment 1 External battery not used...

Page 8: ...ear a click sound Wiring of the configuration cable converter Step 4 For the serial configuration you need to use the USB UART converter adapter order option nr 11 with the provided 3 pin serial cable...

Page 9: ...ed into position Step 6 The opposite side of the USB configuration cable must be connected to the J11 connector s terminal block nr 8 on the figure pins of WM I2 s mainboard nr 14 The wires must be pl...

Page 10: ...nds Step 9 Download the WM I2 Term configuration software and configure the device by following the steps of the Chapter 3 Step 10 Connect the meter sensor wire to the J11 connector s terminal block n...

Page 11: ...l coverage Step 17 Put the enclosure s top cover 2 and fasten the four screws 3 Then the internal tamper switch 10 will be pushed and the device will be turned into configuration mode for 10 minutes d...

Page 12: ...rt transmitting period Thats why you need to run the configuration program on your PC and keep it open and connected to the device on its serial link until the next transmitting while the modem will g...

Page 13: ...or the directory where you are using the program Step 4 Download the WM I2 TERM tool to your computer by using this link from a web browser https www m2mserver com m2m downloads WM I2Term_v0_4_4 zip S...

Page 14: ...nto the popup window Step 4 Define a modem name logical identifier free to choose for the better device identification Use for onsite installation place unique name of identification etc Step 5 Then t...

Page 15: ...one step device list must be in TXT extension text format You will find further icons to control the modem as SETTINGS you can configure the new device parameters for the modem or a define a new firm...

Page 16: ...on settings cellular network settings selection of APN server port and IP address Extended configuration alarm settings life signal checking meter compatibility data sending schedule Templates and oth...

Page 17: ...nfiguration Configuration port Cellular network country code network code choose the SIM provider from the list Step 2 Setup the minimum required fields on the Extended configuration tab and below at...

Page 18: ...the minimum required fields on the Extended configuration tab and below at the Life signal and Time server settings tab Life signal sending IP address where you want to signalling the life signals of...

Page 19: ...D when you connect the battery or pushing the tamper switch at enclosure top cover s close This is useful for testing the communication SIM and APN settings Note that the long operation time of the LE...

Page 20: ...ta storage frequency define the data storage in memory cycle Step 6 At the Validity tab setup the following From Push the Today Now button and set the time manually increase by a few minutes To Push t...

Page 21: ...or file to your computer If you want to send the configuration to the modem choose the Assign to IMEI button At the next connection in case of using the Connection settings Communication SETTINGS Send...

Page 22: ...registered IP address Listener IP address and the Listener port number Serial port connection if you want to configura via serial local port Then choose the USB adapter modem COM port s number and 11...

Page 23: ...guration will be ready to download by the GET button Then the configuration from the module will be downloaded into the WM I2 Term software here and the State will sign by the Sending data message At...

Page 24: ...he log entries can be seen by pushing the icon and choosing the Event Log tab The list can be orderd and saved into various formats here by the buttons 3 9 Refresh modem firmware Step 1 Choose the ico...

Page 25: ...Step 2 Chose the Firmware tab and the Choose Firmware button and browse the firmware file you want to upload to the modem with dwl extension...

Page 26: ...already configured At the next connection Connection settings Connection SETTINGS Sending data the new firmware will be sended to the modem Push to the Assign to IMEI button to save the request for t...

Reviews: