10
WT-009 GSM Remote Control Device
WT-009– USER MANUAL – Rev.2.3 – Technical Support:
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
An alert message will be sent when the increment of alarm counter reaches the alert
value (Default: 500). It is possible to set the alert value up to maximum value of
65535 times. To set the counter alert value of input, you can send the following
commands by SMS message to the unit.
Text Command:
#COA=XXXXX
XXXXX stands for 5 digits value: The number of times
For example, assume you want it sends a counter alert message each time the input has
triggered for 5 times, you would send the following SMS message to the unit.
•
#PWD123456#COA=00005
This input can be programmed to behave differently, it can count the input active high
pulses, generate an alarm message or activate relay. To program the input, you can
send the following commands by SMS message to the unit.
Text Command:
#CTC=F
F stands for input function 1 - 5
Function Descriptions
Function 1:
•
Function as counter
•
Sends a counter alert message once alarm counter reaches the alert value
Function 2:
•
Function as counter
•
Activate the output relay 2 to stay on
•
Sends a counter alert message once alarm counter reaches the alert value
5.1.5 SETTING THE COUNTER ALERT VALUE FOR INPUT
5.1.6 SETTING THE FEATURE FOR INPUT