Connection of the brakes
The brake coils, the brake control units and the monitoring contacts are connected to the mains in the brake terminal box.
3s 3e 3ö
2ö
2s
1s 1e 1ö
2e
3s 3e 3ö
2s 2e 2ö
1s 1e 1ö
3s
3ö
3e
2s
2ö
2e
1s
1ö
1e
Terminal strip for brake monitoring contacts
WAGO 260
cable cross section ... 1,5 mm
2
stripping length required: 8 - 9 mm
black
grey
blue
black
grey
blue
black
grey
blue
black
grey
blue
black
grey
blue
black
grey
blue
not applicable with two brakes
screw plugs 3 x M 20
wear
monitoring
release
monitoring
Switching states of the monitoring switches
brake released
brakes
lining worn
electrical circuit
between _ö and _e
electrical circuit
between _s and _e
no
no
closed
open
yes
no
open
closed
no
yes
open
open
yes
yes
open
closed