4. TYPE CODE
Example
W S G - 10 . X - X1 X2 X3X4 / X5X6X7 - X8X9
W S G - 10 . 1 - 0 0 08 / 45Z - 01
Synchronous motor
Frame type
Overall length
Identifyed by: 1, 2, 3, 4
X1: Customer specic identifer
X2: Motor voltage
0: Suitable for converter supply using a link voltage of 500 ... 620V DC
X5X6X7 / Traction sheave design:
(Traction sheave diameter; width, groove design, groove geometry)
X8X9 Variant code(measuring system, brake manual release,mechanism evacuation device, remote brake release)
e.g. 01: 1313 encoder, with brake manual release, with mechanism evacuation device,w/o remote brake release
Example.
08: 85r/min (with Dt=450mm v=1.0m/s, suspension 2:1)