Translation of the original operating instructions
WITA HE OEM 2 | 40-XX | 60-XX
5
Product data
5.1
Technical data HE OEM 2 40-XX I 60-XX
40-XX
60-XX
Maximum delivery head
4.0 m
6.0 m
Maximum flow rate
2800 l/h
3600 l/h
Power consumption P1 (W)
4.5 - 22
4.5 - 38
Supply voltage
1 x 230V 50Hz
Emission sound pressure level
<43 dB(A)
EEI
≤
0.20
Protection rating
IP 42
Thermal class
TF
≤
Ambient temperature
0 °C to 40 °C
Media temperature
+5 to 110 °C
Maximum system pressure
10 bar (1MPa)
Permitted pumped media
heating water according to VDI 2035
water/glycol mixture 1:1
Supply pressure
Permitted range of temperature
Caution!
The use of inadmissible pumped media can destroy the pump and cause
personal injuries. Always observe the manufacturer's instructions and safety data sheets.
29
Medium Minimum
temperature
supply pressure
< 75 °C
0.05 bar 0.005 MPa 0.5 m
75 °C - 90 °C
0.3 bar
0.03 MPa
3.0 m
90 °C - 110 °C
1.1 bar
0.11 MPa
11.0 m
Temperature range at
Permissible
maximum medium
ambient temperature
temperature
25 °C
5 °C to 110 °C
40 °C
5 °C to 95 °C
Advice
Characteristic HE OEM 2 | 40-XX
H
(m)
4
3.5
3
2.5
2
1.5
1
0.5
0
0
0.5
1
1.5
2
2.5 Qm
3
/h
AUTO
CPII
CPI
PPI
PPII
SI
SII
SIII
Characteristic HE OEM 2 | 60-XX
H
(m)
6
5
4
3
2
1
0
0
0.5
1
1.5
2
2.5
3
3.5 Qm
3
/h
AUTO
CPII
CPI
PPI
PPII
SI
SII
SIII