Translation of the original operating instructions
39
WITA HE OEM 2 | 40-XX | 60-XX
12 Electrical connection
Connect the mains cable to the pump as shown in the figure.
Caution! Mains voltage! Always observe the necessary safety measures,
VDE regulations and local regulations.
The cross-section of the cable must not be smaller than 0.75 mm
2
.
When using fine-wire cables, use wire-end ferrules.
Caution! Danger to life!
Improper assembly and improper electrical connection can be life-threatening. Hazards due to
electrical energy must be excluded.
• Assembly and electrical connection may only be performed by qualified personnel
and in accordance with the applicable regulations (e.g. IEC, VDE etc.)!
• The type of current and voltage must comply with specifications on the type plate.
• Observe the regulations of the local energy suppliers!
• Observe the accident prevention regulations!
• Never pull on the mains cable.
• Do not bend the cable.
• Do not place any objects on the cable.
• When using the pump in systems with temperature above 90°C,
an appropriately heat-resistant connection cable must be used.
• There is a danger of personal injuries due to sharp edges or burrs during performing of
assembly works.
• Never transport the pump by carrying it by the mains cable.
• There is a danger of personal injuries due to dropping the pump.
Click
1
2
3
4
L | N | PE