10-5
SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
alternator can provide maximum power to
properly operate the slideout mechanisms.
If battery charge is sufficient, go to next step.
•
A fuse may be blown in the hydraulic system
control box on the pump, which can be viewed
from beneath the chassis near the left or right
front wheel. See following illustration.
See the Leveling System/Room Extension
Operator’s Manual in your InfoCase for
control box fuse replacement information.
If no fuses are blown, go to the next step.
•
If the batteries and fuses are okay, there may
be a failure in the hydraulic control system or
electrical system, which requires service.
Retract the room using the following
emergency retract procedures and contact
your dealer for service.
SLIDEOUT EMERGENCY
RETRACTION PROCEDURES
Front Slideout Rooms - Emergency
Crank-In Procedure
(If slideout room will not retract using
control switch)
Step 1: Relieve Hydraulic Line Pressure
•
Open the hydraulic pump slideout solenoid
valves to release hydraulic line pressure and
let fluid bypass into the fluid reservoir.
•
The hydraulic pump is located beneath the
entrance steps. To access the pump, remove
the nut from the underside of the top step “lip”
and lift the step upward and remove.
•
The hydraulic pump is equipped with two sets
of hydraulic solenoid valves that control
different systems.
WARNING
Stop engine, place transmission in
neutral position, and apply parking brake
before lying beneath vehicle for this
procedure.
Hydraulic System Control Box
(on pump beneath chassis near LH or RH front tire)
Hydraulic Pump Access - remove nut from
bolt on underside of step and lift off step
Hydraulic Pump beneath Entry Step