![background image](http://html1.mh-extra.com/html/winnebago/2009-adventurer/2009-adventurer_operators-manual_987444119.webp)
10-9
SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
While in the Manual Mode each of the two
room slide arms are activated by pressing and
holding the IN and OUT buttons. The “OUT”
button will retract the front arm. The “IN” button
will retract the back arm. Both IN and OUT
buttons may be held down at the same time to
simultaneously activate both arms to retract the
room. If one side of the room gets ahead of the
other, release that button until the other arm
catches up. The current limiting feature of the
control still functions in the Manual Mode so
each side can be fully retracted until it stops.
Once the room has been retracted, the control
will return to the automatic mode after 60
seconds. You can manually return to automatic
mode by pressing the Service Button.
In the event of a total system failure where
Manual Mode cannot be used, two crank handles
may be used to retract or extend the room. See
Slideout Emergency Retraction - Electric
elsewhere in this section.
Problems Extending the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Extend button.
If an error is detected, the green LED on the
left side of the control panel will blink an error
code. If an error code appears, see the
manufacturer’s user guide provided in your
InfoCase to determine the problem. The error
code must be cleared prior to operating the room.
To clear the error, press the Service Button with
a small tool such as a ballpoint pen, toothpick,
etc. Before operating the room after an error has
been detected, check for obvious faults such as
obstructions before trying to operate the room
again. If the error code appears again, the room
will need to be extended using the crank method
described in the previous section. The crank
method is provided as a means to extend the
room if there is a failure in the automatic system.
If the room must be extended using the crank
method, keep in mind it is likely that it must also
be cranked in to retract. After the outing is
completed and the room is retracted fully, take
the coach to the nearest authorized service center
for inspection.
Further Information
See the Slideout Room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
NOTICE
Never let one side get more than 2 inches
(50 mm) ahead of the other while
retracting.
Green light will flash error code
if system malfunctions*
Service “Reset”
Button*
Red light will flash if
park brake not set
*Not equipped on single mechanism systems