2.2 Connector Pinouts
2.2.1 Isolated DC in Connector
The M-Series HMI uses an isolated 3pin terminal block that accepts 12~24V DC.
2.2.2 Audio Out and Audio In
2.2.3 COM1 Serial Port Connector
The M-Series HMI uses D-SUB 9pin connector to connect serial interfaces.
Serial COM1 settings can be configured for RS-232, RS-422 or RS-485 by jumpers. Refer
to
Ch.2, Configuring Serial Port Settings
section of this user manual for the instruction on
how to configure COM1 serial port settings.
Voltage
Minimum Voltage 12V
Maximum Voltage 24V
Maximum Current 6.6A
Color
Signal Name
Blue
Line In
Green
Line Out
Pin №
RS-232
(Default)
RS-422
RS-485
1
DCD
TxD-
D-
2
RXD
TxD+
D+
3
TXD
RxD+
NC
4
DTR
RxD-
NC
5
GND
GND
GND
6
DSR
NC
NC
7
RTS
NC
NC
8
CTS
NC
NC
9
RI
NC
NC