Print-no. 250 020 1
08/2009
Operating Manual EAV
24
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de
Subject to technical changes
No.
Terminals
1
„12V DC“
2
„0V DC“
3
serial interface
4
serial interface
5
antenna
6
antenna
7
potential free contact C
8
potential free contact NO
Figure 3.4-1: Terminal assignment of the transponder reader
Figure 3.4-2: Installation of the transponder reader
to/from the motor housing
or cable transition
Recommendation:
flush-type box or junction
box for cable connection
cable of 2 x 0.8 mm², length of max. 100 m
[109.36 yd] (up to the last open button/up
to the last access control system)
length and cross section: specification by
the manufacturer of automatic door opener
e. g. Connector
block (via electrical
contractor)
antenna
„Open“
button
automatic
door opener
(optional)
power supply
12V DC/2A
cable of 2 x 0.8 mm²,
length of max. 40 m
[43.744 yd]
antenna cable ready-
made, 2.5 m [2.734 yd]
fixed at the antenna,
cable terminals with
wire and bushes
white
brown
green
yellow
grey
(plus) (minus)
230V/50Hz
N PE
L