Print-no. 250 020 1
08/2009
Operating Manual EAV
14
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de
Subject to technical changes
5
Cable transition KÜ-T-STV
Plug-in and lying buried cable transition
• Inserted by plug-in function with retaining screws
• sash part with spring jacket and cable of 2 m [2.187 yd] or
3.5 m [3.829 yd] (plug for motor housing included)
• for STV-SET KÜ-T-integra-EAV sash part with spring jacket
and cable of 1 m [1.094 yd] (cable end with 8-pole plug)
• frame part with cable of 4 m [4.374 yd]
• lying buried in the airgap
• used as the electric interface (max. 24V DC/2A) between the
sash of the door and the frame
• color: silver/grey
• it must not be relieved for 11 mm airgap [0.433”], suitable
for PVCu and aluminum entrance doors (depends on the
system)
• Recommendation: for timber doors (if applicable also for
PVCu/Vinyl or aluminum doors) use the cover plate F16/
F20, to hide the routering for the cable hole, and to prevent
cable damage
STV-Cable transition KÜ-T-STV FL 2 m
1)
234 148 2
STV-Cable transition KÜ-T-STV-FL 3.5 m
2)
493 042 7
STV-SET Cable transition KÜ-T-integra-EAV
FL 1 m + cable 2 m
3)
493 805 0
STV-Cover plate F16 for KÜ-T-STV
275 846 4
STV-Cover plate F20 for KÜ-T-STV
274 764 2
1)
for use with EAV (if applicable BM), sash part 2 m cable +
plug for motor housing
2)
for use with EAV (if applicable BM), sash part 3,5 m cable +
plug for motor housing
3)
for use with EAV and finger scanner ekey home integra,
sash
part 1 m Kabel + 8-pole plug for control unit ekey home
integra