9
2.
Operation
2.3 Operating modes
2.3.1 OFF mode
The boiler is switched off when in OFF mode. The display
and all buttons, with the exception of the ON/OFF button,
do not function. The LED on the InfoWINplus does not
light up – Fig. 5.
Fig. 5
OFF mode
Fig. 6
Self-test
Self-test
active
Fig. 7
Standard display
Boiler temperature
(Operating phases)
Info
Menu
42
°C
Fig. 8
Display lighting ON
Boiler temperature
(Operating phases)
Lighting ON
42
°C
(Animated symbol)
2.3.2 ON mode, lighting ON, self-test,
lighting OFF
Press the ON/OFF button, lighting and display are swit-
ched on and the self-test starts automatically – Fig. 6.
Self-test:
Sensors, switches and motors are checked during the self-
test.
After a successful self-test, the display shows an operating
phase and the boiler water temperature (standard display).
The LED control lamp lights up green and the desired func-
tions can be selected using the buttons – Fig. 7.
If the self-test was unsuccessful, an information message
(e.g. information, fault, alarm) is displayed (see sections 4).
Lighting ON/OFF
The display lighting switches off automatically after 10
min. (Fig. 8). Pressing one of the six buttons switches the
lighting on again for 10 min.
InfoWINplus identifies and stores the various operating
modes and states. Once the system is switched on, other
operating modes may also be displayed instead of the
standard display, solid fuel or accumulator tank operation;
malfunctions are also displayed. These operating modes
and states are described later in these instructions.