11
2.
Operation
2.4 Operating phases
If the LogWIN is switched on, the following operating phases can be displayed.
2.4.1 Standby
The boiler is ready to heat up (see section 2.8).
After an hour in standby mode, the display is shut down fully, only the green
LED is lit up. The display is switched back on by pressing a button or when
there is a heating requirement.
Fig. 13
Boiler temperature
Cladding door open
Info
Menu
42
°C
2.4.2 Cladding door open
If the cladding door is opened, „Cladding door open“ is displayed for as long as
it remains open.
2.4.3 Ignition ready
1
The boiler is prepared for automatic ignition mode.
Pressing the
Cancel
button cancels the „Ignition ready“ operating phase and
switches to the standby operating phase.
Fig. 14
Boiler temperature
Ignition ready
Info
Cancel Menu
42
°C
1 Only for LogWIN with automatic ignition (accessory).
2.4.4 Ignition phase
1
The boiler is in automatic ignition mode. Once the ignition phase is complete,
the system switches to the „Start procedure“ operating phase.
Fig. 15
Boiler temperature
Ignition phase
Info
Menu
42
°C
2.4.5 Start procedure
The heating process is started automatically once the ignition phase1 is com-
plete or cladding door is closed. Once the heating process operating phase is
complete (at least 30 min.), the system switches into the „Flame stabilisation“
operating phase.
The start procedure is cancelled by pressing the
Cancel
button or automati-
callyafter around 15 min. if the combustion chamber temperature is not incre-
asing sufficiently. The system them switches into the standby operating phase.
2.4.6 Flame stabilisation
Once combustion has been interrupted, an attempt is made to build constant
combustion back up and the system then changes into the „Modulation mode“
or „Standby“ operating mode
Fig. 16
Boiler temperature
Start procedure
Info
Cancel Menu
42
°C
Fig. 17
Boiler temperature
Flame stabilisation
Info
Menu
42
°C
Fig. 12
Boiler temperature
Standby
Info
Menu
42
°C