40
8.
For the service technician/heating technician
8.2.1 Measurement values
The following measurement values are displayed:
Induced draught blower set speed
The nominal speed of the blower is displayed in rpm.
Pos. Prim. airfl.
The position of the primary airflap is displayed in %.
Pos. Sec. airfl.
The position of the secondary airflap is displayed in %.
O2 signal
The O2 signal of the lambda sensor is displayed in %.
O2 heat current
The O2 heat current of the lambda sensor is displayed in A.
8.2.2 Parameters
Menu items in parameters
– Boiler temperature for restart
– Automatic ignition
– Burnout
– LED brightness
Boiler temperature for restart
The blower turns off if the boiler temperature is too high. The restart temperature is the temperature at which the blow-
er turns back on and the boiler resumes normal heating mode.
Factory setting:
75 °C
Possible settings:
65 – 75 °C
Automatic ignition
This adjuster is used to set whether automatic ignition is present or not.
Factory setting: depending on condition on delivery
Burnout
– Automatic detection
The burnout characteristics are determined by the buffer load/switching function module or the MES
PLUS
WVF+ mod-
ule.
If the select mode is set to "Solid fuel operation" on the buffer load/switching function module or MES
PLUS
WVF+
module, then "Burnout" with ember quantity is undertaken. With all other settings, a normal burnout is undertaken.
– Normal
A normal burnout is always undertaken, i.e. the wood is burnt as best as possible until no more remains without
ember quantity.
– Ember quantity
Burnout with ember quantity is always undertaken, i.e. basic embers are maintained to make it easier to start up
again.
LED brightness
LED bar brightness setting on the left of the operating panel next to the InfoWIN Touch.