30
2.
For the Installer
2.4.14 Wood gasification boiler: thermocontrol sensor installation
– Bend the cut-out (feed-through) at the bottom of the side panel so it is not in the way. Route the thermocontrol
sensor (green cable) down the front of the right side panel and through the feed thr
ough – Fig. 46, 47.
– Insert the sensor into the protective tube over the ash door in the front; hook the spring in place – Fig. 48, 49.
Information!
Pull the protruding cable from the thermocontrol sensor back into the side panel or control panel.
The cable must not hang out, so it does not become caught in the ash door.
– Secure the thermocontrol sensor cable to the side panel with a cable tie – Fig. 49.
Fig. 46 Inserting the thermocontrol sensor
at the top
Fig. 47 Threading through thermocontrol
sensor
Fig. 48 Securing the thermocontrol sensor
with spring
2.4.15 Wood gasification boiler: thermocontrol sensor cover installation
– Attach the thermocontrol sensor with 4 self-tapping screws – Fig. 50.
Cut-out feed-
through
Fig. 49 Pull back the cable and secure
with cable ties
Cable tie
Fig. 50 Attaching the cover over the thermocontrol sensor with 4 screws
2 each of
2 each of
Summary of Contents for DuoWIN
Page 15: ...15 2 For the Installer ...
Page 69: ...69 5 Technical Data ...