Displays at startup Troubleshooting
5-2
Cash Media Dispenser Version 4 - Service Manual
01750060162 A
Displays at start-up
No. Meaning
Reaction
OFF
No power supply
Switch on the device.
Controller faulty
Replace the controller.
to
Controller test after Power
On (displays are flashing
and keep changing)
None
Warning: Battery too weak
Replace battery (controller)
Controller faulty
Replace the controller.
Startup of firmware (reset)
Validation of firmware
Check of CMOS
parameters
Test of mechanical compo-
nents
Clearing run
None
-> Error
11
->
Initialization of
photosensors
->
CMOS error PS xx, 22
->
Error 23 ... 28
->
Error 18,19, 71..9A
X
X
Error during photosensor
initialization after change of
configuration or
replacement of controller
(the display alternates
between ’PS’ and the
photosensor number ’XX’).
Check and clear photosensor xx,
try RESET again. Replace module
or controller if necessary.
Power-up completed
without errors.