01750060162 A
Cash Media Dispenser Version 4 - Service Manual
7-1
Maintenance and Service
The information required for carrying out troubleshooting and maintenance on
the individual components can be found in the chapters in this manual.
When carrying out work on components and modules that carry an
electrical charge, this equipment must first be disconnected from the
power supply. Due to the way the device is designed, it is not enough
to switch off the mains switch on the power distributor. In addition, the
safety plug must be disconnected from the power distributor.
Maintenance
Maintenance intervals
Preventive maintenance is required for the CMD-V4 every two years or, at the
latest, after 200,000 transactions.
Performing maintenance
i
All photosensors are only allowed to be cleaned in a dry state.
Preventive maintenance consists of the following:
•
If any error statistics exist, evaluate them to find any serious problems and
take them especially into account during maintenance (possibly replace
components).
•
After maintenance, check the quality of the photosensors with special test
jobs. The quality must be at least service level (status * 2).
•
Remove the cassettes from the CMD-V4.