Initializing the CMD-V4
Start-up
4-4
Cash Media Dispenser Version 4 - Service Manual
01750060162 A
Initializing the CMD-V4
The CMD-V4 saves many parameters in its battery-backed CMOS RAM.
i
This parameter area has to be initialized when components have been
replaced (CMD controller, stacker and output transport (= SAT),
dispensing units or shutter).
The parameters are initialized as follows:
•
Remove all cassettes.
•
Make sure there are no notes in the transport paths (all photosensors must
be free).
•
Check the jumper settings on the CMD controller in accordance with the
system configuration.
•
All connectors on the CMD controller must have been plugged in.
•
Connect jumper 7 on the CMD controller (Clear CMOS) before turning on
the device. Turn on the CMD-V4. Leave jumper 7 connected until the status
display shows the value 'io'.
•
Remove jumper 7 (Clear CMOS) and run through the start-up phase until
'14' appears on the status display. Perform a reset if nothing appears.
•
Now insert the cassettes.
•
Register the cassettes using the product-specific software and calculate
the reference values (see the "Device Overview and Operation" chapter.