background image

Installation with frame for complete integration in wall

 

Installation 

98

 

CINEO C4080 - Installation Guide 

01750223447 D 

4x 

 

 

 

Attach the frame brackets on the side (2) to the device using one hexagon 
socket head cap screw (M6x10) and a washer (6.4x1.6). 

i

 

 If space is restricted use an appropriate tool that is short enough. 

When tightening the screws of the frame brackets, make sure that the 
frame touches the wall. However, if the wall is uneven, you must not 
use force to press it in, since the frame could distort when you secure 
the frame tabs. This could cause the customer panel to grate or jam 
against the inside of the frame when you open it. 

 

 

Plug the connection cable in the socket on the top cover of the 
CINEO C4080 (3). 

 

Summary of Contents for CINEO C4080

Page 1: ...Installation Guide CINEO C4080 Self Service Systems ...

Page 2: ... Please contact the following address giving the order number of this manual in your message Address WINCOR NIXDORF International GmbH Handbuchredaktion R D ACT 12 D 33094 Paderborn Germany Fax 49 0 52 51 693 62 09 E mail manuals hardware wincor nixdorf com any technical questions or problems Please conctact your local representative ...

Page 3: ...September Edition 2013 CINEO C4080 Installation Guide ...

Page 4: ... reserved Any violations give rise to a claim for damages All rights including rights created by patent grants or registration of a utility model or design are reserved Delivery subject to availability right of technical modifications reserved All names of hardware and software products mentioned in this manual are trade names and or trademarks of their respective manufacturers This manual was pro...

Page 5: ...with 4 cassette RM3 15 CINEO C4080 with 5 cassette RM3 16 CINEO C4080 Gas with 5 cassette RM3 17 Installation options of device versions 18 Installation without frame free standing 19 Installation with frame for complete integration 20 Frame for complete integration with attached logo case 20 Frame for complete integration without attached logo case 22 Wall cutout for installation with frame for c...

Page 6: ...ram Rearload 51 Drilling diagram Rearload Gas 52 Power and data cables 53 General 53 Cable lead ins into the safe 54 Power supply 58 Remote status indicator 58 Dimensions of the frame logo 59 Transport route requirements 60 Installation 67 Removing the packing 67 Removing the shipping crate 68 General information 68 Disassembly 69 Mounting sets 70 Mounting set 01750006706 for installation frame fo...

Page 7: ... the installation frame 110 Screwing the device on the installation frame 111 Installing the power and data cables in the device 111 General information 112 Installing the window frame 113 View of the frame completely assembled 113 Pre assembling the frame 117 Mounting the frame 119 Wall fixation 120 Adjustmenting the cover angle 121 Installation with frame for partial integration in the wall 124 ...

Page 8: ...us indicator end 156 Adapting the cable length at the remote status indicator audio 159 Appendix 163 Check list for installation preparations for self service systems 163 General information 164 Preparations 164 Construction work 164 Power and data cables 165 Organizational preparations 165 Delivery and installation 166 Flooring materials on the path of transport 166 Notes concerning installation ...

Page 9: ... C4080 Installation Guide V safety 175 Certification for data transmission 176 FCC rules and Canadian Standard ICES 003 176 UL 291 Level 1 security Container 176 Returning recycling and disposing of used units and consumables 179 ...

Page 10: ...Contents VI CINEO C4080 Installation Guide 01750223447 D ...

Page 11: ...opéen de Normalisation European committee for standardization CFR Code of Federal Regulation CIM Card Identification Module security module CSA Canadian Standards Association D DIN German Institute for Standardization DT Data Transmission E ECB European Certification Body EDM Encryption Decryption Module EEC European Economic Community EMA Intruder alarm system EMC Electromagnetic Compatibility EN...

Page 12: ...the use of certain Hazardous Substances directive on restricting the use of certain harmful substances in electrical and electronic equipment RSI Remote Status Indicator S SELV Safety Extra Low Voltage T TN network Power supply network in accordance with EN 60950 U UL Underwriters Laboratories Inc UPS Uninterruptible Power Supply V VdS Association of Property Insurance Companies ...

Page 13: ...ntload and Rearload with the safe versions UL safe CEN L4 safe CEN III safe CEN IV safe The CINEO C4080 with 5 cassette RM3 in the device versions Frontload and Rearload with the safe versions UL safe CEN L4 safe CEN III safe CEN IV safe The CINEO C4080 Gas with 5 cassette RM3 in the device versions Rearload with the safe versions CEN III safe The following accessories are available Frames for Com...

Page 14: ...hich contain general notes to facilitate use of the device and help avoid operating errors Important safety precautions Please read the following notes carefully before doing any work on the device Be careful not to injure your head when the customer panel or the operating unit door are lifted up Installation note When installing the device and or doing any work on it make sure that it is disconne...

Page 15: ...here is always free access to the sockets used or to the electrical circuit breakers of the house installation In case of an emergency e g damaged cabinets controls or power cables liquids or foreign objects in the device take the following steps Deactivate the device immediately by Switching off the automatic circuit breaker or removing the fuse inset from the fuse holder in the distribution box ...

Page 16: ...s if you want to feed voltage from an external source into prepared cables to install additional electronics e g EMA connection relay panel for external features To clean and maintain the device only use cleaning agents approved by WINCOR NIXDORF International GmbH see chapter Appendix in the operating manual Repairs Repair work may only be carried out by authorized personnel Unauthorized opening ...

Page 17: ...rge the battery Avoid temperatures above 100 C 212 F Do not try to open the battery by force Do not allow the battery to come in contact with water or fire The battery should only be replaced with the same or an equivalent type recommended by WINCOR NIXDORF International GmbH see chapter Appendix section Consumables Dispose of used batteries in compliance with national regulations and the manufact...

Page 18: ...Important safety precautions Introduction 6 CINEO C4080 Installation Guide 01750223447 D ...

Page 19: ...ion Guide 7 Planning the installation This chapter provides you with all the information you need to prepare the installation Device dimensions i All dimensions are specified in millimeters inches The device views are not drawn to scale ...

Page 20: ...ad device version with standard door CINEO C4080 with 4 cassette RM3 784 30 87 790 31 1 1530 60 24 1556 61 26 900 35 43 1022 40 24 1058 41 65 808 31 81 838 32 99 894 35 2 25 0 98 2190 86 22 2178 85 75 678 26 69 770 30 31 1 Installation frame These measures only apply to devices with a barcode reader ...

Page 21: ...lation Guide 9 CINEO C4080 with 5 cassette RM3 784 30 87 790 31 1 1670 65 75 1696 66 77 900 35 43 1022 40 24 1058 41 65 948 37 32 978 38 5 894 35 2 25 0 98 2330 91 73 2318 91 26 678 26 69 910 35 83 1 Installation frame These measures only apply to devices with a barcode reader ...

Page 22: ...door CINEO C4080 with 4 cassette RM3 1022 40 24 900 35 43 1530 60 24 1556 61 26 838 32 99 1058 41 65 894 35 2 25 0 98 2190 86 22 2178 85 75 808 31 81 765 30 12 1108 43 62 790 31 1 784 30 87 1 1 Installation frame These measures only apply to devices with a barcode reader These dimensions only apply for devices with courtesy shelf ...

Page 23: ... 5 cassette RM3 1 784 30 87 790 31 1 900 35 43 1022 40 24 1058 41 65 894 35 2 25 0 98 1108 43 62 1670 65 75 1696 66 77 948 37 32 978 38 5 2330 91 73 2318 91 26 905 35 63 1 Installation frame These measures only apply to devices with a barcode reader These dimensions only apply for devices with courtesy shelf ...

Page 24: ...4 cassette RM3 1 784 30 87 790 31 1 1530 60 24 1556 61 26 808 31 81 838 32 99 25 0 98 2190 86 22 2178 85 75 900 35 43 1022 40 24 1058 41 65 894 35 2 72 43 2 83 1 69 678 26 69 85 3 35 2000 78 74 770 30 31 1 Installation frame These measures only apply to devices with a barcode reader Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 25: ...84 30 87 790 31 1 1670 65 75 1696 66 77 948 37 32 978 38 5 25 0 98 2330 91 73 2318 91 26 72 43 2 83 1 69 900 35 43 1022 40 24 1058 41 65 894 35 2 678 26 69 85 3 35 2140 84 25 910 35 83 1 Installation frame These measures only apply to devices with a barcode reader Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 26: ... 790 31 1 810 31 89 1670 65 75 1696 66 77 948 37 32 978 38 5 25 0 98 2330 91 73 2318 91 26 72 43 2 83 1 69 900 35 43 1022 40 24 1058 41 65 894 35 2 678 26 69 85 3 35 2140 84 25 910 35 83 385 15 16 1 Installation frame These measures only apply to devices with a barcode reader Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 27: ...22 40 24 900 35 43 1530 60 24 1556 61 26 838 32 99 1058 41 65 894 35 2 25 0 98 2190 86 22 2178 85 75 808 31 81 765 30 12 1108 43 62 72 43 2 83 1 69 2000 78 74 678 26 69 85 3 35 1 1 Installation frame These measures only apply to devices with a barcode reader These dimensions only apply for devices with courtesy shelf Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 28: ...65 75 678 26 69 85 3 35 978 38 5 25 0 98 948 37 32 905 35 63 1108 43 62 1058 41 65 1022 40 24 900 35 43 894 35 2 72 43 2 83 1 69 1 2140 84 25 790 31 1 784 30 87 1 Installation frame These measures only apply to devices with a barcode reader These dimensions only apply for devices with courtesy shelf Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 29: ...8 26 69 85 3 35 978 38 5 25 0 98 948 37 32 905 35 63 1108 43 62 1058 41 65 1022 40 24 900 35 43 894 35 2 72 43 2 83 1 69 1 2140 84 25 790 31 1 784 30 87 810 31 89 385 15 16 1 Installation frame These measures only apply to devices with a barcode reader These dimensions only apply for devices with courtesy shelf Standard lock 43 mm 1 69 Customer specific lock max 72 mm 2 83 ...

Page 30: ...your insurance company beforehand In case of doubt contact your Wincor Nixdorf consultant Possible installation Frontload with Rearload with 4 cassette 5 cassette 4 cassette 5 cassette RM3 RM3 Standard Standard Standard Standard Gas Installation without frame free standing yes yes yes yes yes Installation with frame for complete integration no no yes yes no Installation with window frame no no yes...

Page 31: ...lanning the installation Installation options of device versions 01750223447 D CINEO C4080 Installation Guide 19 Installation without frame free standing Standard door cover sheet Design door cover sheet ...

Page 32: ... integration Frame for complete integration with attached logo case CINEO C4080 with 4 cassette RM3 If the CINEO C4080 is installed with a frame for integration in the wall the unit will not be flush with the wall This must be taken into account when laying the flooring see chapter Installation section Installation with frame for complete integration ...

Page 33: ...lation Guide 21 CINEO C4080 with 5 cassette RM3 If the CINEO C4080 is installed with a frame for integration in the wall the unit will not be flush with the wall This must be taken into account when laying the flooring see chapter Installation section Installation with frame for complete integration ...

Page 34: ...plete integration without attached logo case CINEO C4080 with 4 cassette RM3 If the CINEO C4080 is installed with a frame for integration in the wall the unit will not be flush with the wall This must be taken into account when laying the flooring see chapter Installation section Installation with frame for complete integration ...

Page 35: ...lation Guide 23 CINEO C4080 with 5 cassette RM3 If the CINEO C4080 is installed with a frame for integration in the wall the unit will not be flush with the wall This must be taken into account when laying the flooring see chapter Installation section Installation with frame for complete integration ...

Page 36: ...r complete integration If a CINEO C4080 is to be installed with a frame for complete integration in the wall a wall cutout must be provided as shown in the figure below i The wall cutout applies for both frames for complete integration with an attached logo case and frames for complete integration without an attached logo chase Devices with 5 cassette RM3 ...

Page 37: ...device versions 01750223447 D CINEO C4080 Installation Guide 25 Installation with window frame Window frame with attached logo case Frame for a wall thickness of up to 50 mm max 1 97 1 Inside wall device side 2 Outside wall Devices with 5 cassette RM3 ...

Page 38: ...ions of device versions Planning the installation 26 CINEO C4080 Installation Guide 01750223447 D Frame for a wall thickness of up to 160 mm max 6 30 1 Inside wall device side 2 Outside wall Devices with 5 cassette RM3 ...

Page 39: ...on options of device versions 01750223447 D CINEO C4080 Installation Guide 27 Window frame without attached logo case Frame for a wall thickness of up to 50 mm max 1 97 1 Inside wall device side 2 Outside wall Devices with 5 cassette RM3 ...

Page 40: ...ions of device versions Planning the installation 28 CINEO C4080 Installation Guide 01750223447 D Frame for a wall thickness of up to 160 mm max 6 30 1 Inside wall device side 2 Outside wall Devices with 5 cassette RM3 ...

Page 41: ...as shown in the figure below i Between the front of the CINEO C4080 and the wall traverse there has to be a distance of at least 20 mm 0 79 because of the air ventilation This ventilation area should not be overbuild The wall cutout applys for both window frames with an attached logo case and window frames without an attached logo chase Wall thickness 50 mm 1 97 1 Inside wall device side 2 Outside...

Page 42: ...n options of device versions Planning the installation 30 CINEO C4080 Installation Guide 01750223447 D Wall thickness 160 mm 6 3 1 Inside wall device side 2 Outside wall 3 Wall traverse Devices with 5 cassette RM3 ...

Page 43: ...tallation options of device versions 01750223447 D CINEO C4080 Installation Guide 31 Installation with frame for partial integration in the wall Frame for partial integration with attached logo case CINEO C4080 with 4 cassette RM3 ...

Page 44: ...Installation options of device versions Planning the installation 32 CINEO C4080 Installation Guide 01750223447 D CINEO C4080 with 5 cassette RM3 ...

Page 45: ...Planning the installation Installation options of device versions 01750223447 D CINEO C4080 Installation Guide 33 Frame for partial integration without attached logo case CINEO C4080 with 4 cassette RM3 ...

Page 46: ...Installation options of device versions Planning the installation 34 CINEO C4080 Installation Guide 01750223447 D CINEO C4080 with 5 cassette RM3 ...

Page 47: ...a frame for partial integration If a CINEO C4080 is to be installed with a frame for partial integration in the wall a wall cutout must be provided as shown in the figure below i The attached logo case requires a higher wall cutout Wall opening for installing the device with a frame for partial integration with attached logo case Devices with 5 cassette RM3 ...

Page 48: ...of device versions Planning the installation 36 CINEO C4080 Installation Guide 01750223447 D Wall opening for installing the device with a frame for partial integration without attached logo case Devices with 5 cassette RM3 ...

Page 49: ...on the rear side by means of a built in fan Make sure that the distance between the vents and the wall is always at least 50 mm 1 97 see also section Space required for operation and maintenance 1a 1b 1a Air inlet 1b Air inlet with window frame 2 Air outlet Storage if construction work is not yet complete i If interior construction work is not complete when installation is planned the device must ...

Page 50: ...e a distance of at least 3 m 9 8 ft between the electronic article surveillance and the card input of the CINEO C4080 The illustrations below show the necessary operation and maintenance space for the frontload and rearload version Ventilation area Operation and maintenance space Area for frame installation i The area specified for the installation of the frame requires a short tool See illustrati...

Page 51: ... p o s i t D r u c k w e r k 8 0 0 x 2 1 0 Ko mp o n e n t e n s c h l i t t e n A 9 0 0 x 3 4 0 Ko mp o n e n t e n s c h l i t t e n B 7 5 0 x 4 2 0 Ko mp o n e n t e n s c h l i t t e n B 7 5 0 x 4 2 0 2050 80 71 850 33 47 1150 45 28 600 23 62 660 25 98 50 1 97 50 1 97 1030 40 55 50 1 97 120 4 73 120 4 73 400 15 75 950 37 4 650 25 59 ...

Page 52: ...o m p o n e n t e n s c h l i t t e n A 8 5 0 x 3 4 5 Ko mp o n e n t e n s c h l i t t e n B 8 5 0 x 4 9 0 Ko p f e i n h e i t R M3 1 0 0 0 x 4 2 5 Tr e s o r e i n h e i t RM3 7 6 5 x 4 0 0 CCDM Ka s s e t t e n mo d u l 6 9 0 x 1 6 0 1740 68 5 550 21 65 600 23 62 350 13 78 50 1 97 50 1 97 120 4 73 120 4 73 500 19 69 1590 62 6 1700 66 93 800 31 5 1100 43 31 250 9 84 ...

Page 53: ...cinity of lobbies see chapter Appendix section Technical data available underfloor heating energy and or communication cables etc are not damaged when drilling the mounting holes If necessary corresponding arrangements must be made i When selecting the installation site noise emission should be taken into account Fans in operation or the noise produced during a transaction could disturb people in ...

Page 54: ...ved the CEN certification becomes invalid The device must be screwed to the load bearing substructure of the installation site or mounted on a suitable base Using the prescribed mounting materials the following values relating to resistance to removal of the safe from the installation frame are reached Resistance level Resistance grade Minimum force required L 4 50 kN III 50 kN IV 100 kN The opera...

Page 55: ...el showing the resistance level is located on the inside of the safe door Openings which are not used have to be closed by putting in the filling pieces i For mounting material see section Mounting sets in the chapter Installation Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type UL CEN L4 CEN...

Page 56: ...ed with a total of four threaded rods In the following illustration the safe attachment points are dimensioned based on the outer edge of the installation frame The superscript letter in the following illustration stands respectively for F Frontload R Rearload There is only the respective number in the key without the superscript letter The classification to Frontload and Rearload is implied by th...

Page 57: ...3 66 547 21 54 734 28 9 832 32 76 427 16 81 422 16 61 634 24 96 297 11 69 597 23 5 162 6 38 1 Attachment points of installation frame 5 Cable lead ins in the installation frame 2 Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3 Attachment points of safe 4 Attachment point of tear off sensor 8 This side must always point...

Page 58: ...CINEO C4080 Installation Guide 01750223447 D Dimensions of cable areas i In the following illustration see following page the cable feed openings are dimensioned based on the outer edge of the installation frame See illustration on the following page ...

Page 59: ...02 23 7 604 23 78 684 26 93 759 29 88 784 30 87 37 1 46 25 0 98 117 4 61 462 18 19 869 34 21 894 35 2 25 0 98 260 10 24 415 16 34 480 18 9 634 24 96 699 27 52 382 15 04 5 Cable lead ins in the installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 8 This side must always point towards the customer panel ...

Page 60: ...the alarm technician will be able to mount the tear off sensor in the safe easily after the device is installed see also illustration Mounting structure in the corresponding sections of the chapter Installation Ask your alarm technician about the size of the hole and the fitting The maximum diameter for the hole to take the fixing is 20 mm 0 79 in the installation frame 22 mm 0 87 in the safe The ...

Page 61: ...ling diagrams The following figures specify the distance from the edge of the different device versions of the drill holes that are used to secure CINEO C4080 Gas to the installation frame i The installation frame is 3 mm 0 12 smaller than the safe all around See illustration on the following page ...

Page 62: ...F Attachment points of installation frame 2F Alternative attachment points of installation frame 4F Tear off sensor Drilling depths Holes for installation frame min 125 mm 4 92 in the concrete for the hole diameter please refer to the mounting instructions of the caulking cartridge supplied with the mounting set Hole for tear off sensor at least 40 mm 1 57 in concrete Ask your alarm technician abo...

Page 63: ...ttachment points of installation frame 2F Alternative attachment points of installation frame 4F Tear off sensor Drilling depths Holes for installation frame min 125 mm 4 92 in the concrete for the hole diameter please refer to the mounting instructions of the caulking cartridge supplied with the mounting set Hole for tear off sensor at least 40 mm 1 57 in concrete Ask your alarm technician about ...

Page 64: ...ent points of installation frame 2F Alternative attachment points of installation frame 4F Tear off sensor Drilling depths Holes for installation frame min 125 mm 4 92 in the concrete for the hole diameter please refer to the mounting instructions of the caulking cartridge supplied with the mounting set Hole for tear off sensor at least 40 mm 1 57 in concrete Ask your alarm technician about the si...

Page 65: ...tor or must be provided by the customer Please refer to the corresponding illustrations in this guide for the positioning of the cables To lay the cables inside the installation frame and in the safe filling pieces may be removed so that cable sets can be inserted in the cable feed openings see illustration These filling pieces must then be replaced after the cables have been laid The cable exit p...

Page 66: ... cables Planning the installation 54 CINEO C4080 Installation Guide 01750223447 D Cable lead ins into the safe Frontload 5 Cable lead in in the installation frame 6 Cable feed through the floor 8 Customer panel side ...

Page 67: ...223447 D CINEO C4080 Installation Guide 55 1 1 Cable feed opening No power or data cables may be installed below the RM3 inside the safe You will also find details of the position of the cable feed opening for the device in the section Installation frame ...

Page 68: ...Power and data cables Planning the installation 56 CINEO C4080 Installation Guide 01750223447 D Rearload 5 Cable lead in in the installation frame 6 Cable feed through the floor 8 Customer panel side ...

Page 69: ...223447 D CINEO C4080 Installation Guide 57 1 1 Cable feed opening No power or data cables may be installed below the RM3 inside the safe You will also find details of the position of the cable feed opening for the device in the section Installation frame ...

Page 70: ...ed by the customer for supplementary equipment such as a modem 2 3 4 L N PE 1 1 Fuse or automatic circuit breaker 2 CINEO C4080 connnection 3 Modem connection 4 Connection of miscellaneous equipment Remote status indicator The optional remote status indicator comes with a 50 m 164 1 ft connecting cable During planning the position for installation and cable routing must be defined see also chapter...

Page 71: ...allation Guide 59 Dimensions of the frame logo i If the CINEO C4080 was ordered without a logo the logo has to be provided by the customer The visible and the actual logo surface are identical For the dimensions of the device logo please refer to the operating manual of the CINEO C4080 ...

Page 72: ...he forks of the truck must be pushed as far as possible underneath the device from the front or the rear The entire transportation route like the installation site must be checked for load capacity and if necessary strengthened as appropriate before the installation date In order to avoid damage at the floor covering panels e g beaverboard should be laid on the floor for the transport with a palle...

Page 73: ... with 4 cassette RM3 1 1676 65 98 120 4 72 72 43 2 83 1 69 770 30 31 610 24 02 1022 40 24 1058 41 65 590 23 23 100 3 94 790 31 1 1 Shipping crate This measure only applys to devices with a barcode reader On the rearload device the standard lock measures 43 mm 1 69 instead of 72 mm 2 83 of the customer specific lock ...

Page 74: ... with 5 cassette RM3 1 770 30 31 610 24 02 1022 40 24 1058 41 65 72 43 2 83 1 69 1816 71 5 120 4 72 590 23 23 100 3 94 790 31 1 1 Shipping crate This measure only applys to devices with a barcode reader On the rearload device the standard lock measures 43 mm 1 69 instead of 72 mm 2 83 of the customer specific lock ...

Page 75: ...as with 5 cassette RM3 1 770 30 31 610 24 02 1022 40 24 1058 41 65 72 43 2 83 1 69 1816 71 5 120 4 72 590 23 23 100 3 94 810 31 89 1 Shipping crate This measure only applys to devices with a barcode reader On the rearload device the standard lock measures 43 mm 1 69 instead of 72 mm 2 83 of the customer specific lock ...

Page 76: ...s The following illustration should help you determine if the space is sufficient It shows the device on a standard lift truck With the help of the grid 100 mm x 100 mm 3 94 x 3 94 you can draw the actual dimensions of the door and the hallway to find out if there is enough space for transportation Refer to the next page for an example 1540 60 63 540 21 26 810 31 89 790 31 1 CINEO C4080 Gas ...

Page 77: ...ng the installation Transport route requirements 01750223447 D CINEO C4080 Installation Guide 65 Example CINEO C4080 with minimum transport path measurements 830 32 68 1900 74 8 1540 60 63 540 21 26 790 31 1 ...

Page 78: ...t route requirements Planning the installation 66 CINEO C4080 Installation Guide 01750223447 D Example CINEO C4080 Gas with minimum transport path measurements 850 33 46 1900 74 8 1540 60 63 540 21 26 810 31 89 ...

Page 79: ...standard door or standard cover sheet i All dimensions are specified in millimeters inches The figures are not drawn to scale Contact the person in charge of planning the installation to verify that all preparatory work has been done completely and correctly and that none of the required power and data cables are missing Removing the packing Remove the packing material of the CINEO C4080 Dispose o...

Page 80: ... Guide 01750223447 D Removing the shipping crate General information For transportation the device is equipped with a shipping crate This must be removed before installation i To move the device push against the sides of the safe only as shown in the illustration below ...

Page 81: ...e shipping crate 4x Remove the screws of the shipping crate from underneath Lift the device with the help of the lift truck 1 Don t move the device in this situation it risks to tip over Remove the shipping crate of CINEO C4080 Gas 2 Dispose of the shipping crate which is no longer needed according to the regulations of your country ...

Page 82: ...rocedure for mounting the installation frame or the installation rack described in the sections of the installation versions assumes that the provided mounting set 01750006706 is used If you are using different fastening materials please follow the instructions included with those items Item Quantity required Mounting set for installation frame supplied with installation frame Caulking cartridge t...

Page 83: ...ns assumes that the provided mounting set is used If you are using different fastening materials please follow the instructions included with those items Item Quantity required Caulking cartridge A caulking gun is not included in the delivery package 1 Threaded rod M16x300 DIN 976 property class 10 9 4 Hexagon nut M16 DIN 934 10 9 4 Washer A 17 DIN 125 St 4 Mounting set 01750217972 Safe on install...

Page 84: ... cassette 4 cassette 5 cassette RM3 RM3 Standard Standard Standard Standard Gas Installation without frame free standing yes yes yes yes yes Installation with frame for complete integration no no yes yes no Installation with window frame no no yes yes no Installation with frame for partial integration in the wall yes yes yes yes no i Observe the necessary operation and maintenance space for the va...

Page 85: ...9 referring to the installation frame 23 mm 0 91 It is mandatory that the area underneath the control panel is completely empty because of the air inlet i The installation area must be flat and on one level with the surrounding floor Any differences in floor height in the installation area must be leveled out with rustproof shims for example Securing the installation frame The installation frame n...

Page 86: ... below i The installation frame must be secured using one threaded rod per group of holes A to D The installation frame is secured with a total of four threaded rods The superscript letter in the following illustration stands respectively for F Frontload R Rearload There is only the respective number in the key without the superscript letter The classification to Frontload and Rearload is implied ...

Page 87: ...allation frame 5 Cable lead ins in the installation frame 2 Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3 Attachment points of safe 4 Attachment point of tear off sensor 8 This side must always point towards the customer panel Drill the required four holes and the hole for the tear off sensor if necessary see followi...

Page 88: ...safe does not become detached the threaded rods of the installation frame must be fastened in the concrete foundation The drilled holes in the concrete foundation must have a depth of at least 125 mm 4 92 for the installation frame see illustration below For the hole diameter please refer to the mounting instructions of the caulking cartridge The drilled hole in the concrete foundation must have a...

Page 89: ... set for installation frame 4 Installation frame 8 Top surface of finished floor The overall drilling depth depends on the constructional situation The threaded rods must be anchored at least 125 mm in the load bearing concrete Excess lengths must be shortened correspondingly or if necessary in case of deeper floor anchorages be replaced by equivalent threaded rods Clean the bore holes as specifie...

Page 90: ... example i The threaded rods must protrude at a minimum 24 mm 0 94 and at a maximum 25 mm 0 98 i If the mounting set is not provided use equivalent fastening material Insert the cartridge for the tear off sensor if required i The space inside the installation frame allows cable lead in through cable ducts in the floor Frontload Rearload 5 Cable lead in in the installation frame 6 Cable feed throug...

Page 91: ...side 10 of the installation frame as in the example shown here Make sure that the connecting cables are laid loosely and are not crushed by the installation frame 4x Push the installation frame onto the threaded rods 1 as shown in the illustration as an example Secure the installation frame using one hexagon nut and one washer for each of the 4 attachment points 2 for material see section Mounting...

Page 92: ...on remove those parts inside the unit which secure its components during transportation see enclosed information sheet Pull out the RM3 see chapter Basic Operation in the operating manual Screwing the device on the installation frame 2x 2 4x 1 Align the device to the installation frame and screw the main safe with four pan head screws and four washers 1 and the secondary safe with two pan head scr...

Page 93: ...rther procedure for CEN installation Attach the VdS ECB S label for the installation frame inside the safe door below the existing VdS ECB S label of the safe The VdS ECB S label for the mounted installation frame is included with the installation frame After mounting the installation frame and the device fill out the Confirmation of Installation The Confirmation of Installation is included with t...

Page 94: ...INEO C4080 Installation Guide 01750223447 D Give the Confirmation of Installation to the operator of the device i The operator needs the Confirmation of Installation for submitting it to the insurance company General information Close the device ...

Page 95: ...llation area must be flat and on one level with the surrounding floor Any differences in floor height in the installation area must be leveled out with rustproof shims for example Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type UL CEN L4 CEN III CEN IV These attachment points are at position...

Page 96: ...de 01750223447 D i The installation frame must be secured using one threaded rod per group of holes A to D The installation frame is secured with a total of four threaded rods The superscript letter in the following illustration stands respectively for R Rearload See illustration on the following page ...

Page 97: ... 2 0 2 1R Attachment points of installation frame 5 Cable lead ins in the installation frame 2R Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3R Attachment points of safe 4R Attachment point of tear off sensor 8 This side must always point towards the customer panel 9 Wall Drill the required four holes and the hole for...

Page 98: ...nsure that the safe does not become detached the threaded rods of the installation frame must be fastened in the concrete foundation The drilled holes in the concrete foundation must have a depth of at least 125 mm 4 92 for the installation frame see illustration below For the hole diameter please refer to the mounting instructions of the caulking cartridge The drilled hole in the concrete foundat...

Page 99: ...nsor 7 Mounting set for installation frame 4 Installation frame 8 Top surface of finished floor The overall drilling depth depends on the constructional situation The threaded rods must be anchored at least 125 mm in the load bearing concrete Excess lengths must be shortened correspondingly or if necessary in case of deeper floor anchorages be replaced by equivalent threaded rods Clean the bore ho...

Page 100: ...ridge Illustration as an example i The threaded rods must protrude at a minimum 24 mm 0 94 and at a maximum 25 mm 0 98 i If the mounting set is not provided use equivalent fastening material Insert the cartridge for the tear off sensor if required i The space inside the installation frame allows cable lead in through cable ducts in the floor 5 Cable lead in in the installation frame 6 Cable feed t...

Page 101: ... the safe door side 10 of the installation frame as in the example shown here Make sure that the connecting cables are laid loosely and are not crushed by the installation frame 4x Push the installation frame onto the threaded rods 1 as shown in the illustration as an example Secure the installation frame using one hexagon nut and one washer for each of the 4 attachment points 2 for material see s...

Page 102: ...supplied with the frame 1 2 Remove the blind plugs in positions 1 and 2 on both sides of the device by levering them up from the side 3 and pulling them out 4 Push the device onto the installation frame Ensure that no cables are damaged in the process Open the safe door see chapter Basic Operation in the operating manual If it is necessary for the installation remove those parts inside the unit wh...

Page 103: ...ry safe with two pan head screws and two washers 2 to the installation frame for material see section Mounting sets UL 1 M16 x 40 2 M16 x 40 CEN 1 M16 x 45 2 M16 x 40 Installing the power and data cables in the device Undo the two screws 1 and remove the filling piece of the safe underneath Feed the cable into the safe 1 Replace the filling piece of the installation frame position 6a 2 and fix it ...

Page 104: ...he device fill out the Confirmation of Installation The Confirmation of Installation is included with the installation frame Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form i If there is no fax machine available the form has to be faxed to this number at a later point in time Give the Confirmation of Installation to the operator of the device ...

Page 105: ...nstallation Guide 93 Installing the frame View of the frame completely assembled With attached logo case 1 4 5 3 6 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Middle frame plate 3 Cover angle adjustment only after the frame is attached to the device 6 Lower frame plate ...

Page 106: ...n 94 CINEO C4080 Installation Guide 01750223447 D Without attched logo case 1 4 5 3 6 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Middle frame plate 3 Cover angle adjustment only after the frame is attached to the device 6 Lower frame plate ...

Page 107: ...rame brackets position 6 in the illustration View of the frame completely assembled on the left and on the right side using two round head screws M4x6 each 1 4x Attach the middle frame brackets position 5 in the illustration View of the frame completely assembled on the left and on the right side using two round head screws M4x6 each in the lower hole pattern 2 ...

Page 108: ...far as possible in the direction show by the arrow 6 If this is not the case loosen the four laterally screws 4 and the two upper screws 5 Push the cover angle 3 as far as possible in the direction of the arrow 6 Fasten at least one of the previously loosened screws on right on the left and on top Frame for complete integration with attached logo case only Raise the cable of the light box 7 and fi...

Page 109: ...ide 97 Mounting the frame Push the frame from the front in the direction of the arrow 1 up to the customer panel Lift the frame a little and slide it carefully over the customer panel and let go i Be careful not to scratch the customer panel and not to damage the connection cable Push the frame against the wall ...

Page 110: ...s restricted use an appropriate tool that is short enough When tightening the screws of the frame brackets make sure that the frame touches the wall However if the wall is uneven you must not use force to press it in since the frame could distort when you secure the frame tabs This could cause the customer panel to grate or jam against the inside of the frame when you open it Plug the connection c...

Page 111: ...he wall you need to fix the wall on its rear side 1 2 1 2 Loosen screws 1 and 2 Move the two wall fixations as fas as possible outward 3 Fasten the screws 1 and 2 again Adjustmenting the cover angle Adjust the cover angle inside of the frame to compensate mounting tolerances of the installation frame Then the cover angle is screwed to the traverse inside of the device ...

Page 112: ...Installation with frame for complete integration in wall Installation 100 CINEO C4080 Installation Guide 01750223447 D Loosen the screws 1 and 2 of the cover angle 3 ...

Page 113: ...ew points in the housing cover are visible Fasten it to the device with three Taptite fillister head screw TT M4x10 5 Tighten the four screws on the left and on the right 6 and the two upper screws 7 If light shines through the corner areas of the frame out of the room in the back the corners can be closed with silicone on the rear side of the frame if necessary Silicone is not included in the shi...

Page 114: ... and on one level with the surrounding floor Any differences in floor height in the installation area must be leveled out with rustproof shims for example Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type UL CEN L4 CEN III CEN IV These attachment points are at position 1 Mounting points 2 serv...

Page 115: ... 103 i The installation frame must be secured using one threaded rod per group of holes A to D The installation frame is secured with a total of four threaded rods The superscript letter in the following illustration stands respectively for R Rearload See illustration on the following page ...

Page 116: ...R AR DR CR BR 23 0 91 830 32 38 23 0 91 360 14 17 1 97 50 73 5 2 87 0 2 1R Attachment points of installation frame 5 Cable lead ins in the installation frame 2R Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3R Attachment points of safe 4R Attachment point of tear off sensor 8 This side must always point towards the cus...

Page 117: ... 3 160 183 5 7 2 0 2 1R Attachment points of installation frame 5 Cable lead ins in the installation frame 2R Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3R Attachment points of safe 4R Attachment point of tear off sensor 8 This side must always point towards the customer panel 9 Wall Drill the required four holes an...

Page 118: ...e safe does not become detached the threaded rods of the installation frame must be fastened in the concrete foundation The drilled holes in the concrete foundation must have a depth of at least 125 mm 4 92 for the installation frame see illustration below For the hole diameter please refer to the mounting instructions of the caulking cartridge The drilled hole in the concrete foundation must have...

Page 119: ...ng set for installation frame 4 Installation frame 8 Top surface of finished floor The overall drilling depth depends on the constructional situation The threaded rods must be anchored at least 125 mm in the load bearing concrete Excess lengths must be shortened correspondingly or if necessary in case of deeper floor anchorages be replaced by equivalent threaded rods Clean the bore holes as specif...

Page 120: ...ration as an example i The threaded rods must protrude at a minimum 24 mm 0 94 and at a maximum 25 mm 0 98 i If the mounting set is not provided use equivalent fastening material Insert the cartridge for the tear off sensor if required i The space inside the installation frame allows cable lead in through cable ducts in the floor 5 Cable lead in in the installation frame 6 Cable feed through the f...

Page 121: ...r side 10 of the installation frame as in the example shown here Make sure that the connecting cables are laid loosely and are not crushed by the installation frame 4x Push the installation frame onto the threaded rods 1 as shown in the illustration as an example Secure the installation frame using one hexagon nut and one washer for each of the 4 attachment points 2 for material see section Mounti...

Page 122: ... the frame 1 2 3 Remove the blind plugs in positions 1 and 2 on both sides of the device by levering them up from the side 3 and pulling them out 4 Push the device onto the installation frame Ensure that no cables are damaged in the process Open the safe door see chapter Basic Operation in the operating manual If it is necessary for the installation remove those parts inside the unit which secure ...

Page 123: ...two pan head screws and two washers 2 to the installation frame for material see section Mounting sets UL 1 M16 x 40 2 M16 x 40 CEN 1 M16 x 45 2 M16 x 40 Installing the power and data cables in the device Undo the two screws 1 and remove the filling piece of the safe underneath Feed the cable into the safe 1 Replace the filling piece of the installation frame position 6a 2 and fix it with the earl...

Page 124: ...l out the Confirmation of Installation The Confirmation of Installation is included with the installation frame Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form i If there is no fax machine available the form has to be faxed to this number at a later point in time Give the Confirmation of Installation to the operator of the device i The operato...

Page 125: ...the window frame View of the frame completely assembled With an attached logo case and wall thickness up to 50 mm 1 96 1 4 6 3 5 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Frame bracket 3 Cover angle adjustment only after the frame is attached to the device 6 Window crossbar ...

Page 126: ...n Guide 01750223447 D With an attached logo case and wall thickness up to 160 mm 6 30 1 4 6 3 5 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Frame bracket 3 Cover angle adjustment only after the frame is attached to the device 6 Window crossbar ...

Page 127: ...stallation Guide 115 Without an attached logo case and wall thickness up to 50 mm 1 96 1 4 5 3 6 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Frame bracket 3 Cover angle adjustment only after the frame is attached to the device 6 Window crossbar ...

Page 128: ...Guide 01750223447 D Without an attached logo case and wall thickness up to 160 mm 6 30 1 4 6 3 5 2 1 sensor at the frame 4 Connection cable for lighting 2 Wall fixation 5 Frame bracket 3 Cover angle adjustment only after the frame is attached to the device 6 Window crossbar ...

Page 129: ...he right side 2 using two round head screws M4x6 each i Before the frame can be mounted you must ensure that the cover angle 3 is moved as far as possible in the direction show by the arrow 6 If this is not the case loosen the four laterally screws 4 and the two upper screws 5 Push the cover angle 3 as far as possible in the direction of the arrow 6 Fasten at least one of the previously loosened s...

Page 130: ...Installation with window frame Installation 118 CINEO C4080 Installation Guide 01750223447 D Window frame with attached logo case only Raise the cable of the light box 7 and fix it ...

Page 131: ...other variants proceed in the same way Open the customer panel by approximately 30 see operating manual Push the frame from the front in the direction of the arrow 1 up to the customer panel Lift the frame a little and slide it carefully over the customer panel and let go i Be careful not to scratch the customer panel and not to damage the connection cable Push the frame against the wall Close the...

Page 132: ...tightening the screws of the frame brackets make sure that the frame touches the wall However if the wall is uneven you must not use force to press it in since the frame could distort when you secure the frame tabs This could cause the customer panel to grate or jam against the inside of the frame when you open it Plug the connection cable in the socket on the top cover of the CINEO C4080 3 Wall f...

Page 133: ...n screws 1 and 2 Move the two wall fixations as fas as possible outward 3 Fasten the screws 1 and 2 again Adjustmenting the cover angle Adjust the cover angle inside of the frame to compensate mounting tolerances of the installation frame Then the cover angle is screwed to the traverse inside of the device ...

Page 134: ...Installation with window frame Installation 122 CINEO C4080 Installation Guide 01750223447 D Loosen the screws 1 and 2 of the cover angle 3 ...

Page 135: ...the housing cover are visible Fasten it to the device with three Taptite fillister head screw TT M4x10 5 Tighten the four screws on the left and on the right 6 and the two upper screws 7 If light shines through the corner areas of the frame out of the room in the back the corners can be closed with silicone on the rear side of the frame if necessary Silicone is not included in the shipment ...

Page 136: ...i The installation area must be flat and on one level with the surrounding floor Any differences in floor height in the installation area must be leveled out with rustproof shims for example Securing the installation frame The installation frame needs to be anchored in the floor at four attachment points regardless of the safe construction type UL CEN L4 CEN III CEN IV These attachment points are ...

Page 137: ... rod per group of holes A to D The installation frame is secured with four threaded rods The superscript letter in the following illustration stands respectively for F Frontload R Rearload There is only the respective number in the key without the superscript letter The classification to Frontload and Rearload is implied by the illustration See illustration on the following page ...

Page 138: ... 0 91 23 0 91 1 Attachment points of installation frame 5 Cable lead ins in the installation frame 2 Alternative attachment points of installation frame 6 Area for cables 7 Cable feed openings underneath the installation frame 3 Attachment points of safe 4 Attachment point of tear off sensor 8 This side must always point towards the customer panel 9 Wall Drill the required four holes and the hole ...

Page 139: ... ensure that the safe does not become detached the threaded rods of the installation frame must be fastened in the concrete foundation The drilled holes in the concrete foundation must have a depth of at least 125 mm 4 92 for the installation frame see illustration below For the hole diameter please refer to the mounting instructions of the caulking cartridge The drilled hole in the concrete found...

Page 140: ...sensor 7 Mounting set for installation frame 4 Installation frame 8 Top surface of finished floor The overall drilling depth depends on the constructional situation The threaded rods must be anchored at least 125 mm in the load bearing concrete Excess lengths must be shortened correspondingly or if necessary in case of deeper floor anchorages be replaced by equivalent threaded rods Clean the bore ...

Page 141: ...llustration as an example i The threaded rods must protrude at a minimum 24 mm 0 94 and at a maximum 25 mm 0 98 i If the mounting set is not provided use equivalent fastening material Insert the cartridge for the tear off sensor if required i The space inside the installation frame allows cable lead in through cable ducts in the floor Frontload Rearload 5 Cable lead in in the installation frame 6 ...

Page 142: ...nd the safe door side 10 of the installation frame as in the example shown here Make sure that the connecting cables are laid loosely and are not crushed by the installation frame 4x Push the installation frame onto the threaded rods 1 as shown in the illustration as an example Secure the installation frame using one hexagon nut and one washer for each of the 4 attachment points 2 for material see...

Page 143: ...supplied with the frame 3 1 2 Remove the blind plugs in positions 1 2 and 3 on both sides of the device by levering them up from the side 4 and pulling them out 5 Push the device onto the installation frame Ensure that no cables are damaged in the process Open the safe door see chapter Basic Operation in the operating manual If it is necessary for the installation remove those parts inside the uni...

Page 144: ...dary safe with two pan head screws and two washers 2 to the installation frame for material see section Mounting sets UL 1 M16 x 40 2 M16 x 40 CEN 1 M16 x 45 2 M16 x 40 Installing the power and data cables in the device Undo the two screws 1 and remove the filling piece of the safe underneath Feed the cable into the safe 1 Replace the filling piece of the installation frame position 6a 2 and fix i...

Page 145: ... the device fill out the Confirmation of Installation The Confirmation of Installation is included with the installation frame Fax the filled out and signed Confirmation of Installation form to the fax number provided on the form i If there is no fax machine available the form has to be faxed to this number at a later point in time Give the Confirmation of Installation to the operator of the devic...

Page 146: ...on Guide 01750223447 D Installing the frame for partial integration in the wall View of the frame completely assembled With attached logo case 1 7 5 2 6 4 3 1 sensor at the frame 5 Middle frame plate 2 Cover angle 6 Lower frame plate 3 Wall fixation 7 Mounting brackets 4 Connection cable for lighting ...

Page 147: ...partial integration in the wall 01750223447 D CINEO C4080 Installation Guide 135 Without attched logo case 1 7 5 3 6 2 1 Right part of frame 5 Middle frame plate 2 Left part of frame 6 Lower frame plate 3 Top part of frame 7 Mounting brackets ...

Page 148: ... the frame and the sides of the frame positions 1 2 and 3 in the illustration View of the frame completely assembled on the left and on the right side according to the illustration below using the round head screws M4 x 6 1 8x Frame for partial integration with without attached logo case Attach the upper mounting brackets position 7 in the illustration View of the frame completely assembled with t...

Page 149: ...ts position 5 in the illustration View of the frame completely assembled on the left and on the right side using two round head screws M4x6 each in the lower hole pattern 3 4x Attach the lower frame brackets position 6 in the illustration View of the frame completely assembled on the left and on the right side using two round head screws M4x6 each 4 4x ...

Page 150: ... with an attached logo case is displayed in the following The mounting of other variants proceed in the same way Push the frame from the front in the direction of the arrow 1 up to the customer panel Lift the frame a little and slide it carefully over the customer panel and let go i Be careful not to scratch the customer panel Push the frame against the wall ...

Page 151: ...asher 4 3 i If space is restricted use an appropriate tool that is short enough When tightening the screws of the frame brackets make sure that the frame touches the wall However if the wall is uneven you must not use force to press it in since the frame could distort when you secure the frame tabs This could cause the customer panel to grate or jam against the inside of the frame when you open it...

Page 152: ...ion 140 CINEO C4080 Installation Guide 01750223447 D Wall fixation After you installed the frame into the wall you need to fix the wall on its rear side 1 2 1 2 Loosen screws 1 and 2 Move the two wall fixations as fas as possible outward 3 Fasten the screws 1 and 2 again ...

Page 153: ...ribed for a CINEO C4080 Rearload with design cover sheet as an example the procedure is the same for a CINEO C4080 Frontload with design cover sheet Any deviations are specifically described at the respective position Preparatory work Courtesy shelf plastic 2x Slide the two hexagon serrated flange nuts M6 into the courtesy shelf plastic as shown above 1 ...

Page 154: ...ounting the courtesy shelf Open the design door of the CINEO C4080 Frontload see chapter Basic Operation in the operating manual or detach the front cover sheet of the CINEO C4080 Rearload see previous section 2x Attach the courtesy shelf using two pan head screws M6x30 1 Close the front door of the CINEO C4080 Frontload or replace the front cover sheet of the CINEO C4080 Rearload and fasten the s...

Page 155: ...s preparation is a correct functioning of the seismic vibration detector not given If the seismic vibration detector should be installed by an alarm technician this information must be handed over to him Remove screws 1 and 2 on the cover Pull the cover in the direction shown by the arrow away from the safe wall and remove it Install the seismic vibration detector 1 on the provided place according...

Page 156: ...cause electric shocks and burns Therefore remove watches rings and other metallic objects before replacing the battery Only use tools with insulated handles Never combust a battery because it may explode Don t open or damage the battery effluent electrolyte is harmful for skin and eyes i Before the start up of the CINEO C4080 there has to be a plug connection inside the UPS The mounting position o...

Page 157: ...l the housing cover on the right forwards 1 until it is released of the right and the middle catches Remove the housing cover aside 2 Connect the plug connection 1 Reinstall the housing cover on the left 1 and press it against the UPS on the right until it locks into position ...

Page 158: ...Start up Installation 146 CINEO C4080 Installation Guide 01750223447 D ...

Page 159: ...em Quantity required 1 Remote Status Indicator Standard 01750047663 with 50 m 164 1 ft connecting cable dimensions 101 2 x 45 7 x 27 mm 3 98 x 1 8 x 1 06 W x H x D 1 2 Phillips screws SPAX 2 5 x 20 mm 0 098 x 0 787 countersunk head 2 3 Fixings Ø 4 mm 0 16 2 i The enclosed mounting material is used to secure the indicator to masonry or wooden paneling ...

Page 160: ...tabs behind them disengage Remove the front cover 3 forwards When drilling the mounting holes take note of the constructional situation energy media line etc Position the lower section and mark the points where it is to be secured In masonry only Drill the necessary bores drill depth 20 mm 0 79 drill diameter 4 mm 0 16 and insert the enclosed fixings in the holes Secure the lower section to the wa...

Page 161: ...res Open the device see the device s operating manual Route the connecting cable through the cable feed openings or the lead ins into the device see the section for the appropriate installation version in the chapter Installation Lay the connecting cable in the device to the relay panel for external features so that it cannot be damaged when components are pulled out Shorten the connecting cable i...

Page 162: ...r 150 CINEO C4080 Installation Guide 01750223447 D Connect the individual wires to the relay panel for external features as follows 11121314 Pin Name 11 Wire RED 11 RED LIGHT 12 Wire WHITE 12 YELLOW LIGHT 13 Wire GREEN 13 GREEN LIGHT 14 Wire BLACK 14 GND Close the device ...

Page 163: ...ge 1 3 2 Pos Item Quantity required 1 Remote Status Indicator Audio 01750069332 with 50 m 164 1 ft connecting cable dimensions 118 x 96 5 x 40 5 mm 4 65 x 3 8 x 1 59 W x H x D 1 2 Phillips screws SPAX 4 x 40 mm 0 157 x 1 575 half round screws 2 3 Fixings Ø 6 mm 0 24 2 i The enclosed mounting material is used to secure the indicator to masonry or wooden paneling ...

Page 164: ...bottom and pull the panel downwards out of the front cover When drilling the mounting holes take note of the constructional situation energy media line etc Position the back panel and mark the points where it is to be secured i Allow sufficient space to install the connecting cable on the right approx 20 mm 0 79 In masonry only Drill the necessary bores drill depth 40 mm 1 57 drill diameter 6 mm 0...

Page 165: ...h the screws supplied and mount the front cover on the back panel as described above under removal 2 1 i An adhesive label with the number 1 is applied in the factory Remove the required label 1 and apply it to the space provided 2 on the audio remote status indicator Lay the connecting cable of the audio Remote Status Indicator to the appropriate device ...

Page 166: ...or the lead ins into the device see the section for the appropriate installation version in the chapter Installation Lay the connecting cable in the device so that it cannot be damaged when components are pulled out Shorten the connecting cable if so required to the appropriate length see section Shortening the cable ends Marking on wires i The wires are marked with an adhesive label at the end as...

Page 167: ... 01750223447 D CINEO C4080 Installation Guide 155 Connect the individual wires to the relay panel for external features as follows 11121314 Pin Name 11 Wire RED 11 RED LIGHT 12 Wire WHITE 12 YELLOW LIGHT 13 Wire GREEN 13 GREEN LIGHT 14 Wire BLACK 14 GND Close the device ...

Page 168: ...0 mm 2 36 of the cable insulation and 7 mm 0 28 of the individual wire insulation The individual wire ends must be twisted Connect the cable as described in the section Installation Adapting the cable length at the standard remote status indicator end 2 3 1 Use a screwdriver to press carefully through openings 1 and 2 until the tabs behind them disengage Remove the front cover 3 forwards 1 Release...

Page 169: ... cable end as shown in the following diagram 60 23 62 4 5 0 18 You must strip 60 mm 2 36 of the cable insulation and 4 5 mm 0 18 of the individual wire insulation The individual wire ends must be twisted Lead the connecting cable through the opening in the lower section and secure it with the strain relief Marking on wires i The wires are marked with an adhesive label at the end as follows RED RED...

Page 170: ...O C4080 Installation Guide 01750223447 D Connect the individual wires as follows Pin Name 1 Wire RED RED LIGHT 2 Wire WHITE YELLOW LIGHT 3 Wire GREEN GREEN LIGHT 4 Wire BLACK GND Press the front cover onto the lower section Ensure that no wires are damaged in the process ...

Page 171: ... D CINEO C4080 Installation Guide 159 Adapting the cable length at the remote status indicator audio Loosen screw 1 Move the back panel 2 to one side at the bottom and pull the panel downwards out of the front cover 2 Remove the two screws 1 and move the board 2 to one side ...

Page 172: ...e the connecting cable with the spacer from cable guide 2 Remove the spacer from the connecting cable see arrow Shorten the connecting cable to the desired length Push the spacer back on the cable Shorten the cable end as shown in the following diagram 25 0 98 4 5 0 18 You must strip approx 25 mm 0 98 of the cable insulation and 4 5 mm 0 18 of the individual wire insulation The individual wire end...

Page 173: ...ve label at the end as follows RED RED LIGHT WHITE YELLOW LIGHT GREEN GREEN LIGHT BLACK GND Connect the individual wires as follows 1 Pin Name 1 Wire RED RED LIGHT 2 Wire WHITE YELLOW LIGHT 3 Wire GREEN GREEN LIGHT 4 Wire BLACK GND Press the connecting cable with the spacer into the cable guide 2 Mount the board and the back panel as described above under removal ...

Page 174: ...Shortening the cables Installing the Remote Status Indicator 162 CINEO C4080 Installation Guide 01750223447 D ...

Page 175: ... number or system s serial number This check list has been created for all self service systems Most questions can be answered yes or no Some empty space is provided in the section Notes concerning installation preparation for your convenience if you want to note any questions or drafts After checking off all items copy this list send it to your head of operations and make arrangements for an inst...

Page 176: ...llation area Are there cavities in the installation area cable duct raised floor Is the operation and maintenance space sufficient Is the equipment screened from external light sunlight Is a video surveillance system to be installed Is a door opener system to be installed Preparations Construction work yes no OK Is the securing of cash dispensers in the raw concrete ensured CEN standard Is the fra...

Page 177: ...nnection prepared Have the camera connection and the door opener been provided Organizational preparations yes no OK Is the generation prepared on the host Has the MM module or CIM06 been ordered and is it available Have the encryption decryption or EPP keys been prepared Is the paper and money ready for start up Have you discussed the diameter of the hole that is to be drilled and the fixing to b...

Page 178: ... obstacles in front of the building If so how many Are there steps or obstacles inside the building If so how many Are there mats or grates at the entrance Flooring materials on the path of transport please check off Screed concrete Carpet Raised floor Marble floor Tiles Others Please enter the width of the most narrow door Please enter the width of the most narrow hallway Checked by customer Chec...

Page 179: ...Appendix Check list for installation preparations for self service systems 01750223447 D CINEO C4080 Installation Guide 167 Notes concerning installation preparation ...

Page 180: ...Check list for installation preparations for self service systems Appendix 168 CINEO C4080 Installation Guide 01750223447 D ...

Page 181: ...on conditions Electrical characteristics of the supply network Line voltage range 110 120 V 220 240 V Rated frequency 50 60 Hz 50 60 Hz Network type TN network with PE conductor TN network with PE conductor Permissible tolerance for rated voltage 10 to 6 10 to 6 Permissible tolerance for rated frequency 1 1 ...

Page 182: ... A 3 6 A Apparent power input 300 VA 740 VA 330 VA 740 VA Real power 280 W 690 W 270 W 670 W Power factor 0 76 0 84 Leakage current 3 5 mA 3 5 mA 3 5 mA 3 5 mA Protection class I I Type of system connection wall outlet Country specific protective contact plug or CEE plug pursuant to IEC 60309 Country specific protective contact plug or CEE plug pursuant to IEC 60309 Fuse Protection against melting...

Page 183: ... 3 kN m 14 3 kN m 2 1 lbf in 2 1 lbf in CEN L4 safe Device weight 1129 kg 2489 lb 1129 kg 2489 lb Surface load 16 2 kN m 16 2 kN m 2 4 lbf in 2 4 lbf in CEN III safe Device weight 1199 kg 2643 4 lb 1199 kg 2643 4 lb Surface load 17 2 kN m 17 2 kN m 2 5 lbf in 2 5 lbf in CEN IV safe Device weight 1229 kg 2709 5 lb 1229 kg 2709 5 lb Surface load 17 6 kN m 17 6 kN m 2 6 lbf in 2 6 lbf in Weight figur...

Page 184: ...EN L4 safe Device weight 1189 kg 2621 3 lb 1189 kg 2621 3 lb Surface load 16 97 kN m 16 97 kN m 2 5 lbf in 2 5 lbf in CEN III safe Device weight 1309 kg 2885 9 lb 1309 kg 2885 9 lb Surface load 18 7 kN m 18 7 kN m 2 8 lbf in 2 8 lbf in CEN III Gas safe Device weight 1409 kg 3106 3 lb Surface load 20 2 kN m 3 lbf in CEN IV safe Device weight 1339 kg 2952 lb 1339 kg 2952 lb Surface load 19 2 kN m 19...

Page 185: ...Air temperature C F Relative humidity r h Operation indoors 5 to 40 5 to 85 41 to 104 Transport 25 to 60 15 to 98 13 to 140 Storage 5 to 40 15 to 98 41 to 140 Mechanical environmental conditions pursuant to EN 60721 Class Comments Operation 3M2 Building without significant vibrations caused by other objects Transport in original packaging 2M2 All types of commercial vehicles and trailers as well a...

Page 186: ...nt when selecting the installation location Fans or the noise volume associated with a transaction can be perceived as disruptive when standing directly near the device these noises may have to be reduced through sound protection measures e g sound protection walls etc They must comply with the environmental conditions that apply to the specific device see above and the maintenance areas see chapt...

Page 187: ...ached to the product or its package indicates that the product complies with the requirements of the following EC directives EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS Directive 2011 65 EC The corresponding statement of compliance has been issued by WINCOR NIXDORF International GmbH Heinz Nixdorf Ring 1 33106 Paderborn Germany Notes concerning radio interference suppression an...

Page 188: ...equency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense UL 291 Level 1 security Container In order to meet guideline UL 291 ensure the fo...

Page 189: ...D CINEO C4080 Installation Guide 177 12 7 mm thick or an equivalent structure so as to restrict the removal of the teller machine from the building The release mechanism of the attachment devices shall only be accessible when the door of the security container is open ...

Page 190: ...bly and recyclability have been taken into account This saves resources and relieves the strain on the environment Saving energy Please switch on devices that need not be constantly running only when they are actually needed They should also be turned off when they are not needed for longer periods of time Disposing of used consumables Please dispose of printer consumables batteries and cleaning a...

Page 191: ...tifications 01750223447 D CINEO C4080 Installation Guide 179 Returning recycling and disposing of used units and consumables Details regarding the return and recycling of used units and consumables can be obtained from your local branch office ...

Page 192: ...Compliance with standards and certifications Appendix 180 CINEO C4080 Installation Guide 01750223447 D ...

Page 193: ...01750223447 D CINEO C4080 Installation Guide Notes ...

Page 194: ...Published by WINCOR NIXDORF International GmbH D 33094 Paderborn Order No 01750223447 D 1 GB ...

Reviews: