background image

3180-10

18

60706-238

WINCO, Inc.

 warrants to the original purchaser for 24 months* that goods manufactured or supplied by it 

will be free from defects in workmanship and material, provided such goods are installed, operated and 
maintained in accordance with 

WINCO’s

 written instructions.  

* NOTE: Units used in prime power are warranted for 120 day  Units that are resold are not cov-
ered under this warranty.  Any further warranty whether expressed or implied, rest solely with the 
reseller.

WINCO, Inc

. warrants to the ultimate purchaser and each subsequent purchaser that the evaporative 

emission control system is designed, built, and equipped so as to conform at the time of original sale to 
the then current evaporative emission requirements. In addition it is free from defects in materials and 
workmanship that may keep it from meeting these requirements. This evaporative emission control sys-
tem is warranted for two years. If an evaporative emission related part on your equipment is defective, 
the part will be repaired or replaced by 

WINCO Inc.

WINCO’s

 sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to 

the repair of the product.  At 

WINCO’s

 option, material found to be defective in material or workman-

ship under normal use and service will be repaired or replaced.  For warranty service, return the product 
within 24 months from the date of purchase, transportation charges prepaid, to your nearest 

WINCO 

Authorized Service Center or to 

WINCO Inc

. at Le Center, Minnesota.

THERE IS NO OTHER EXPRESS WARRANTY.

To the extent permitted by law, any and all warranties, including those of merchantability and fi tness for 
a particular purpose, are limited to 24 months from date of purchase.  In no event is 

WINCO

 liable for 

incidental or consequential damages.

Note:  Some states do not allow limitation on the duration of implied warranty and some states do not 
allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not 
apply in every instance.  This warranty gives you specifi c legal rights which may vary from state to state.

WINCO

 reserves the right to change or improve it products without incurring any obligations to make 

such changes or improvements on products purchased previously

.

EXCLUSIONS:

WINCO 

does not warrant Engines.  Engines are covered exclusively by the warranties of their respective 

manufacturers.

WINCO 

does not warrant Batteries, or Other Component Parts that are warranted by their respective 

manufacturers.

WINCO 

does not warrant modifi cations or alterations which were not made by WINCO Inc.

WINCO 

does not warrant products which have been subjected to misuse and/or negligence or have 

been involved in an accident.

This warranty does not include travel time, mileage or labor for removal or reinstallation of a WINCO 
product from its application.

24 MONTH LIMITED WARRANTY

Summary of Contents for Home power HPS6000HE

Page 1: ...INSTALLATION AND OPERATORS MANUAL HPS6000HE I BI FUEL GENERATOR...

Page 2: ...ion 8 INITIAL START UP Basic Operation 9 Manual Starting Gasoline only 9 Electric Starting Gasoline 10 Electric Starting NG 11 Stopping Storage 11 Operating Speed 12 CONNECTING THE LOADS 12 Wiring 13...

Page 3: ...dren c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel on...

Page 4: ...making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long as they have been certified and meet current code DO NOT attempt to ope...

Page 5: ...otify the trans portation company immediately request proper pro cedures for filing a concealed damage claim Title to the equipment and responsibility for filing a claim rests with you when a generato...

Page 6: ...upplier The fuel source should be as close as possible to the outdoor operating location This will reduce the installation cost of fuel runs Connect the fuel supply line to the inlet of the fuel deman...

Page 7: ...te Length of Fuel Line Fuel Line Size less than 50 feet 3 4 inch black pipe 50 to 200 feet 1 inch black pipe Allow an additional 3 feet for each standard elbow Do not use street ells restrictive Consu...

Page 8: ...he unit If you intend to use the power plant s electric start system required when using NG you will need to purchase and install a battery to operate it Units equipped with a recoil or rope start wil...

Page 9: ...de the engine If the oil level drops below a certain point the low oil module on the engine will shut it down This low oil warning system will automatically stop the engine before the oil level reache...

Page 10: ...the fuel supply by moving the fuel lever to the ON position 3 Move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position 4 Turn the engine switch...

Page 11: ...mer blended gasoline Using gasoline left over from winter may cause the unit to vapor lock STOPPING AND STORAGE 1 Move the engine switch to the OFF position 2 Turn off the fuel supply valve 3 Before e...

Page 12: ...oltmeter and a frequency meter or tachometer and be sure the voltage and speed are correct Lower voltage may damage both the generator and any load connected to it Running the engine at ex cessively h...

Page 13: ...receptacle on these units are designed to power both 120 or 240 volt loads The plug for this receptacle can be wired for either 120 volt 240 volt or a combination of 120 and 240 volt loads depending...

Page 14: ...nually or every 100 hours Service more often under dusty conditions WARNING EQUIPMENT DAMAGE Never start or run the engine with the air filter re moved a Remove the wing nut from the air cleaner cover...

Page 15: ...alified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS a Bearing The bearing used in these generators is a heavy duty double sealed ball bearing They require no maintenance or lu...

Page 16: ...o output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective rotor field Short...

Page 17: ...17 3180 10 60706 238 WIRING DIAGRAM...

Page 18: ...rn the product within 24 months from the date of purchase transportation charges prepaid to your nearest WINCO Authorized Service Center or to WINCO Inc at Le Center Minnesota THERE IS NO OTHER EXPRES...

Page 19: ...RER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission related parts on your equipment are defective the parts will be repaired or repla...

Page 20: ...3180 10 20 60706 238 WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com...