60706-238

4.  

Spark Plug

: Replace annually or every 300 hours 

of operation.  Always replace with the same spark 
plug that came in the engine and check gap before 
installing.  Spark plug gap is 0.030”.  Poor spark will 
also occur if spark plug wire does not fi t fi rmly on 
spark plug.  If this happens, reform the terminal to fi t 
fi rmly on spark plug tip.

5.  

Carbon Canister:  

Designed to collect, store, and 

dispose of fuel vapors created in the fuel tank / fuel 
system.  The canister should last the life of the unit as 
long as it stays dry.

GENERATOR CARE

Proper care and maintenance of the generator is 
necessary to ensure a long trouble free life.

1.  

Exercising The Generator

 - The generator 

should be operated every three to four weeks.  It 
should be operated for a period of time suffi cient to 
warm the unit up and to dry out any moisture that has 
accumulated in the windings.  If left, this moisture can 
cause corrosion in the winding.  Frequent operation 
of the engine generator set will also insure that the 
set is operating properly should it be needed in an 
emergency.

2.  

Generator Maintenance

 - Any major genera-

tor service, including the installation or replacement 
of parts, should be performed only by a qualifi ed 
electrical service technician.  

USE ONLY FACTORY 

APPROVED REPAIR PARTS

.

a.  Bearing - The bearing used in these generators  
 

is a heavy duty double sealed ball bearing.     

 

They require no maintenance or lubrication.

b.  Receptacles - Quality receptacles have been  
 

utilized.  If a receptacle should become cracked  

 

or otherwise damaged, replace it.  Using dam-   

 

aged or cracked receptacles can be both dan- 

 

gerous to the operator and destructive to the   

 equipment.

CLEANING

Remove dirt and debris with a cloth or brush.  DO 
NOT use high pressure spray to clean either the 
engine or the generator.  This high pressure spray 
could contaminate the fuel system and the generator 
components.

1.  Keep the air inlet screen on both the engine and
generator free of any dirt or debris to insure proper 
cooling.  At least yearly, remove the blower housing 
on the engine and clean the chaff and dirt out of the 
engine cooling fi ns and fl ywheel.  Clean more often 
if necessary.  Failure to keep these areas clean may 
cause overheating and permanent damage to the 
unit.

2.  Periodically clean muffl er area to remove all grass, 
dirt and combustible debris to prevent a fi re.

3.  On engine muffl ers equipped with spark arresters, 
the spark arrester must be removed every 50 hours 
for cleaning and inspection.  Replace if damaged

GASKET

AIR CLEANER
COVER

PAPER FILTER
ELEMENT

FOAM FILTER
ELEMENT

WING NUT

STANDARD DUAL-FILTER-
ELEMENT TYPE

WING NUT

.

if

Summary of Contents for Home power HPS6000HE

Page 1: ...INSTALLATION AND OPERATORS MANUAL HPS6000HE I BI FUEL GENERATOR...

Page 2: ...ion 8 INITIAL START UP Basic Operation 9 Manual Starting Gasoline only 9 Electric Starting Gasoline 10 Electric Starting NG 11 Stopping Storage 11 Operating Speed 12 CONNECTING THE LOADS 12 Wiring 13...

Page 3: ...dren c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel on...

Page 4: ...making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long as they have been certified and meet current code DO NOT attempt to ope...

Page 5: ...otify the trans portation company immediately request proper pro cedures for filing a concealed damage claim Title to the equipment and responsibility for filing a claim rests with you when a generato...

Page 6: ...upplier The fuel source should be as close as possible to the outdoor operating location This will reduce the installation cost of fuel runs Connect the fuel supply line to the inlet of the fuel deman...

Page 7: ...te Length of Fuel Line Fuel Line Size less than 50 feet 3 4 inch black pipe 50 to 200 feet 1 inch black pipe Allow an additional 3 feet for each standard elbow Do not use street ells restrictive Consu...

Page 8: ...he unit If you intend to use the power plant s electric start system required when using NG you will need to purchase and install a battery to operate it Units equipped with a recoil or rope start wil...

Page 9: ...de the engine If the oil level drops below a certain point the low oil module on the engine will shut it down This low oil warning system will automatically stop the engine before the oil level reache...

Page 10: ...the fuel supply by moving the fuel lever to the ON position 3 Move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position 4 Turn the engine switch...

Page 11: ...mer blended gasoline Using gasoline left over from winter may cause the unit to vapor lock STOPPING AND STORAGE 1 Move the engine switch to the OFF position 2 Turn off the fuel supply valve 3 Before e...

Page 12: ...oltmeter and a frequency meter or tachometer and be sure the voltage and speed are correct Lower voltage may damage both the generator and any load connected to it Running the engine at ex cessively h...

Page 13: ...receptacle on these units are designed to power both 120 or 240 volt loads The plug for this receptacle can be wired for either 120 volt 240 volt or a combination of 120 and 240 volt loads depending...

Page 14: ...nually or every 100 hours Service more often under dusty conditions WARNING EQUIPMENT DAMAGE Never start or run the engine with the air filter re moved a Remove the wing nut from the air cleaner cover...

Page 15: ...alified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS a Bearing The bearing used in these generators is a heavy duty double sealed ball bearing They require no maintenance or lu...

Page 16: ...o output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective rotor field Short...

Page 17: ...17 3180 10 60706 238 WIRING DIAGRAM...

Page 18: ...rn the product within 24 months from the date of purchase transportation charges prepaid to your nearest WINCO Authorized Service Center or to WINCO Inc at Le Center Minnesota THERE IS NO OTHER EXPRES...

Page 19: ...RER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission related parts on your equipment are defective the parts will be repaired or repla...

Page 20: ...3180 10 20 60706 238 WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com...

Reviews: