background image

WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN  56057 507-357-6821

SERVICE DEPT. 507-357-6831

www.wincogen.com

INSTALLATION AND 

OPERATORS

DE SERIES

GENERATORS

MANUAL

MANUAL KEY START AND DSE4510 ELECTRIC START

Summary of Contents for DE SERIES

Page 1: ...INCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS DE SERIES GENERATORS MANUAL MANUAL KEY START AND DSE4510 ELECTRIC START...

Page 2: ...lected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefull...

Page 3: ...oper instruction B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operating this unit in rain or snow E Use only three prong grounded plugs and e...

Page 4: ...ations Oil Type See Lubrication section in this manual Oil Capacity 8 6 Quarts Cooling System 50 50 mix SPECIFICATIONS DE20I4 MODEL DE20I4 3 DE 20I4 4 DE20I4 17 DE20I4 18 Generator Wattage 20 000 20 0...

Page 5: ...ifications Oil Type See Lubrication section in this manual Oil Capacity 13 5 Quarts Cooling System 50 50 mix DE65F4 MODEL DE65F4 3 DE 65F4 4 DE65F4 17 DE65F4 18 Generator Wattage 55 000 62 000 62 000...

Page 6: ...ont cover of this manual for future reference and for identification whenever requesting field or factory assistance Primary fields needed for assistance are complete model number and serial number EN...

Page 7: ...ting the generator Due to the different designs configurations options weights site conditions and available material handling equipment specific lifting instructions are not provided for each individ...

Page 8: ...mes larger than the radiator face The extra air inlet area is required to minimize restriction and to provide combustion air for the engine Do not block fresh air intakes with other equipment as this...

Page 9: ...start up A customer supplied 12 Volt battery is required to complete the installation Installation of the highest CCA rated battery within the correct BCI group will increase cold weather starting pe...

Page 10: ...make sure that a new battery is fully charged before installing it on a generator set Failure to do so can cause damage to the engine control module in the generator set All connections must be clean...

Page 11: ...r and the load Based on wire type and temperature rating Wire has been derated for 40 C ambient temperature Wire Temperature Rating CB AMP Cu Conductor AI Conductor kW Voltage PH 75 C 90 C 75 C 90 C 2...

Page 12: ...to verify correct installation before starting the engine Engine oil Fill as required with proper grade qty Engine coolant Fill as required with proper mixture Unit mounting base properly bolted down...

Page 13: ...tion Warning alarms are self resetting when the fault condition is removed The icon will appear steady in they display SHUTDOWN Shutdowns are critical alarm conditions that stop the engine and draw th...

Page 14: ...fter the Safety On timer has expired Generator Under Frequency The generator frequency has fallen below the pre set pre alarm setting after the Safety On timer has expired Generator Over Frequency The...

Page 15: ...ng the engine Engine oil Fill as required with proper grade qty Engine coolant Fill as required with proper mixture Unit mounting base properly bolted down Clearance for service and maintenance on all...

Page 16: ...16 OPM 103 REV B KEY START PANEL SCHEMATIC WIRE 91 IS NOT INCLUDED WITH THE DE45 DE90 MODELS CONTROL BOX AC WIRING...

Page 17: ...EMATIC DE20 DE30 ENGINE HARNESS SCHEMATIC 7 7 51 725 0 67 57 5 3 8 3803 8 1 2 35 668 5 6 1 5 22 17 7 03 6 1 5 8 9 6 1 5 2 3 8 6 1 725 2 3 8 6 5 67 57 62 12 2 22 17 127 6 22 17 1 2 35 6685 6 7 67 1 5 6...

Page 18: ...18 OPM 103 REV B 4510 ELECTRIC START PANEL...

Page 19: ...19 OPM 103 REV B THREE PHASE AC WIRE HIGH AND LOW WYE THREE PHASE AC WIRING DELTA SINGLE PHASE 311 WINDING...

Page 20: ...d fitness for a particular purpose are limited to 12 months or 1000 hours which ever occurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some st...

Reviews: