20 Washbasin fitting
WimTec SMART
Hy
Plus
EN
SMART
Hy
Plus
Configuring the functions
Setting controls
1. Interval control
for the interval of the sta-
gnation flush, default 12 h
(setting range 0,5 h - 24 h).
2. Minimum flushing
duration control
for the duration of the
stagnation flush, default 30 s
(setting range 10 s - 180 s).
Rule applies to all controls:
Move counterclockwise to
decrease the setting.
Move clockwise to
increase the setting.
!
Function activation – DIP switch 1–6:
DIP switch
Function
Factory setting
Description
1
Active range (ON =
15 cm
, OFF = 12 cm)
ON
Page 22
2
Cleaning stop
OFF
Page 23
3
Continuous flow
OFF
Page 24
4
Intelligent stagnation flush
ON
Page 25
5
Flushing stop (ON = 10 min, OFF =
1 min
)
OFF
Page 26
6
Shut-off delay (ON = 3 s, OFF =
1 s
)
OFF
Page 26
DIP switches:
6
h
0,5
24
3
12
60
s
10
180
30
120