Washbasin fitting
WimTec SMART
Hy
Plus
27
EN
SMART
Hy
Plus
Function description
The time set at the minimum flushing duration control (see page 20)
can be monitored through the flashing control LED.
Minimum flushing duration visualisation:
i
Tip:
While the set minimum flushing duration is visualised
through the flashing control LED, the fitting is out of service.
The fitting will resume normal operation as soon as the
visualisation is finished.
By changing the position of DIP switch 4 to ‚OFF‘ the intel-
ligent stagnation flush will be disabled and visualisation of
minimum flushing duration will be aborted.
1
DIP switch 4
By changing the DIP switch position to ‚ON‘ the control LED
starts flashing every second for the time set at the minimum
flushing duration control.
2
Minimum flusing duration control (if DIP switch 4 = ‚ON‘)
When altering the time set at the minimum flushing duration
control, 5 s after the last adjustment occured the control LED
starts flashing every second.
Activate minimum flushing duration visualisation:
12
34
56
ON
OF
F