Installation and operating instructions Wilo-Port 800 39
PRODUCT DESCRIPTION English
3.8. Dimensions
Fig. 2: Dimension drawing
ø880
ø900
ø820
ø110
ø200
500
755
R 1¼“
850
1140
1120
1750
ø160
ø160
110
100
120
120
120
ø880
ø900
ø820
ø110
ø200
R 1¼“
ø160
ø160
110
100
120
120
120
500
1350
1255
1620
1640
2250
The height dimensions increase by the upward protruding part of
the selected pump cover.
3.9. Scope of delivery
• Pump chamber with complete pipework, consisting of
•
Discharge pipe with surface coupling, 90° non-return ball valve
and pressure connection
• Shut-off device
• Cross member
• Chain (lifting equipment for pump installation)
• Installation materials for pumps
• Installation and operating instructions
NOTE:
For use as a pumping station, accessories are required that have to
be ordered separately.
3.10. Accessories
•
Clamp bolting for connection to a PE discharge pipe
•
Pump chamber extension
•
Pump cover in classes A15, B125 or D400 (in accordance with
EN 124)
• Operating crank for shut-off device
•
Flush connection with Storz C connection
•
Flush connection extension
•
Vacuum relief valve
•
Level control using:
• Dynamic pressure bell, optionally with bubbling-through system
• Level sensor
•
Float switch
• Macerator pump
• Switchgear (depending on level control device)
•
Ex cut-off relay and Zener barrier as separate accessories for con
-
nection of float switch or level sensor in potentially explosive areas
• Alarm switchgear
•
Flash light
For further information, see catalogue.
Fig. 2