36
WILO SE 06-2015 V05 DIN A4
English
PRODUCT DESCRIPTION
2.7. Sound pressure
The pump chamber itself does not produce any noise. However, the
actual sound pressure of the system depends on several factors,
e.g. pump installed, installation depth, attachment of accessories
and piping, duty point etc.
We recommend that the operator carries out an additional meas-
urement when the system is running at its duty point an under all
operating conditions.
CAUTION: Wear ear defenders!
According to applicable laws and regulations, ear protection
must be worn if the sound-pressure level is 85 dB(A) or more!
The end-user must make sure that this is complied with!
2.8. Standards and guidelines used
The pump chamber is subject to various European directives and
harmonised standards. Refer to the EC declaration of conformity for
precise information about these.
There are also various additional regulations that are prerequisites
for use, installation and dismantling of the pump chamber.
2.9. CE marking
The CE marking is attached to the rating plate.
3. Product description
The pump chamber is manufactured with the utmost care and is
subject to continuous quality assurance. Fault-free operation is
guaranteed if it is installed and maintained correctly.
3.1.
Intended use and fields of application
RISK of explosive atmosphere!
Sewage containing faeces can lead to gas accumulation in the
collection reservoir, which can ignite as a result of improper
installation and operation.
When using the system for sewage containing faeces, the local
directives and regulations for Ex protection must be checked
and observed.
RISK due to explosive media!
Collection of explosive media (e.g. petrol, kerosene etc.) is
strictly prohibited. The pump chamber is not designed for these
media.
Combined with a submersible pump, the Wilo-Port 800 acts as
a pumping station for sewage containing faeces and free of faeces
in a domestic setting. Its field of application is in drainage of building
discharge points and sites below the backflow level, where the sew
-
age cannot drain into the public channel due to natural fall.
Intended use includes compliance with this manual. Any other use is
considered to be outside the intended use.
3.2.
Improper use and fields of application
WARNING - Injuries hazardous to health!
Because of the materials used, the pump chamber is not suitable
for pumping of drinking water.
•
If it comes into contact with sewage, there is a risk of damage to
health.
• Do not use the pump chamber inside buildings.