Faults, causes and remedies
54
WILO SE 2019-03
DANGER
Danger due to fluids hazardous to health!
Danger of death in case of pumps with fluids hazardous to health! Wear the follow-
ing protective equipment while performing the work:
• Closed safety goggles
• Breathing mask
• Protective gloves
⇒ The equipment listed here is the minimum requirement, observe the spe-
cifications of the work regulations! The operator must make sure that the
personnel have received and read the work regulations!
DANGER
Risk of death due to electrocution!
Improper conduct when carrying out electrical work can lead to death due to electric
shock! Electrical work must be carried out by a qualified electrician in accordance
with the locally applicable regulations.
DANGER
Risk of fatal injury due to dangerous lone working practices!
Work in chambers and narrow rooms as well as work involving risk of falling are dan-
gerous work. Such work may not be carried out autonomously! A second person
must be present for safety reasons.
WARNING
No persons are allowed to be present inside the working area of the
pump!
Persons may suffer (serious) injuries while the pump is in operation! No persons may
therefore be present inside the working area. If persons must enter the working area
of the pump, the pump must be decommissioned and secured against being
switched on again without authorisation.
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
Fault: Pump does not start
1. Electricity supply interrupted or short-circuit/earth fault in the cable or motor
winding.
⇒ Have the connection and motor checked by a qualified electrician and replace
if necessary.
2. Tripping of fuses, of the motor protection switch or the monitoring equipment
⇒ Have the connection and the monitoring equipment checked by a qualified
electrician and change it if necessary.
⇒ Have the motor protection switches and fuses installed and adjusted accord-
ing to the technical specifications by a qualified electrician and reset monitor-
ing equipment.
⇒ Check the impeller to make sure that it runs smoothly, clean the hydraulics if
necessary.
Fault: Pump starts up, motor protection trips after short period
1. Motor protection switch set incorrectly.
Summary of Contents for Padus PRO M08L/T039-540/A
Page 2: ......
Page 3: ...3 Deutsch 4 English 31 Fran ais 58 Svensk 86 Polski 112 Rom n 141 P 169...
Page 171: ...ru Wilo Padus PRO 171 1 1 1 1 2 1 3 1 4 www wilo com legal 2...
Page 172: ...ru 172 WILO SE 2019 03 2 1 1...
Page 173: ...ru Wilo Padus PRO 173 2 2 2 3...
Page 174: ...ru 174 WILO SE 2019 03 2 4 RCD RCD RCD 2 5 2 6 2 7...
Page 175: ...ru Wilo Padus PRO 175 2 8 40 C 104 F 85 A 85 A 2 9...
Page 176: ...ru 176 WILO SE 2019 03 2 10 2 11 16 18 3 3 1 10 pH 4 8 3 2...
Page 180: ...ru 180 WILO SE 2019 03 Fig 2 5 3...
Page 181: ...ru Wilo Padus PRO 181 15 C 60 C 5 F 140 F 90 5 C 25 C 41 F 77 F 40 50 3 6 180 6 6 6 1 6 2 6 3...
Page 182: ...ru 182 WILO SE 2019 03 6 4 IP 6 4 1 6 6 4 1 1...
Page 183: ...ru Wilo Padus PRO 183 1 2 6 4 2 1 2 3 4 5 6 7 Fig 3 1 2 Storz 3 Storz 4 5 6 7 Storz 1 2 3 4 5...
Page 184: ...ru 184 WILO SE 2019 03 6 4 3 6 5 6 5 1 RCD RCD RCD...
Page 186: ...ru 186 WILO SE 2019 03 6 5 4 1 5 6 5 4 2 5 30 6 5 5 7 7 1 7 2 7 3...
Page 188: ...ru 188 WILO SE 2019 03 10 2 5 1 8 8 1 8 2 8 3 3 C 37 F 1...
Page 189: ...ru Wilo Padus PRO 189 2 5 8 4 8 4 1 1 2...
Page 190: ...ru 190 WILO SE 2019 03 3 4 5 6 8 4 2 1 2 30 10 in 3 4 5 6 9...
Page 192: ...ru 192 WILO SE 2019 03 9 4 1 4000 15000 9 4 2 9 5 9 5 1 9 5 2...
Page 193: ...ru Wilo Padus PRO 193 9 5 3 9 5 4 9 5 4 1 0 9 5 5...
Page 194: ...ru 194 WILO SE 2019 03 1 Fig 7 1 1 2 3 4 5 6 7 8 5 9 ft lb 8 9 8 5 9 ft lb 9 5 6 10...
Page 195: ...ru Wilo Padus PRO 195 1 2 1 2 3 4...
Page 196: ...ru 196 WILO SE 2019 03 5 6 7 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11...
Page 197: ...ru Wilo Padus PRO 197 1 2 3 4 5 6 7 8 11 12 12 1 12 2 12 3...
Page 198: ...ru 198 WILO SE 2019 03 www wilo recycling com...