SCH & SCL
Oil Furnaces
–
Furnace Manual
38
670-000-006-1007
13
Owner’s information
The furnace must be inspected and started by a qualified service technician
only, at the beginning of the ANNUAL heating season.
The service technician must perform
annual service and maintenance on the furnace to ensure reliable operation. Failure to service and maintain the furnace and
system could result in equipment failure, causing severe personal injury, death or substantial property damage.
As the owner, you nee to be aware of the following requirements. You must inspect and clean or replace the furnace filter
monthly, as described below, and perform the other inspection procedures as well. Failure to maintain a clean filter will result in
cycling of the furnace and could lead to a no-heat condition. Failure to perform this maintenance could result in substantial
property damage.
Follow all of the procedures below. Failure to comply could result in severe personal injury, death or substantial property damage.
Operating the furnace
1. The furnace should operate automatically on call for heat from the room thermostat.
2. If the furnace oil burner should shut down on flame failure, the burner primary control will lock out. Ask your service technician
to show you the correct procedure to reset the primary control button. NEVER push the button more than once in an attempt
to start the burner after lockout. Continued lockout of the control means something is wrong with the burner, controls or oil
system. The condition must be corrected by a qualified service technician.
Daily inspection
1. Verify there are no combustible materials in the furnace room or near the furnace.
2. Verify the air openings to the furnace room are not obstructed in any way.
3. Verify the furnace seems to be operating normally. Notify your service technician immediately if you notice any abnormal
behavior.
4. Verify that there are no obstructions to the vent termination/air intake on the outside of the building.
Monthly – inspect and clean/replace filter
1. Ask your service technician to show you the correct way to remove and clean your furnace filter. Replace the filter if you are
unable to thoroughly clean it.
To shut down furnace
1. Set the room thermostat to its lowest setting.
2. Turn off the disconnect switch in the 120-VAC power line to the furnace.
3. If the burner will be shut down for an extended time, tightly close all oil valves.
4. Refer to burner manual for any additional instructions.
W-T Manufacturing
8201 W. Calumet Rd. • Milwaukee, WI 53223
Summary of Contents for SCH High Boy
Page 12: ...SCH SCL Oil Furnaces Furnace Manual 12 670 000 006 1007...
Page 13: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 13...
Page 14: ...SCH SCL Oil Furnaces Furnace Manual 14 670 000 006 1007...
Page 25: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 COMPONENTS AND REPLACEMENT PARTS 25...
Page 39: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 X40132 Rev D 39...