SCH & SCL
Oil Furnaces
–
Furnace Manual
34
670-000-006-1007
12 Dimensions and ratings
Figure 7
Model SCH-105 / 160 dimensional data – ALL DIMENSIONS IN INCHES
Flue pipe
W idth
Depth
Height
W idth
Depth
W idth
Depth
dia.
A
B
C
D
E
F
G
SCH-105
21"
24½"
48
19 ¾"
19¾"
18¾"
18-11/16"
3"
SCH-160
25"
28½"
58¼"
23¾"
23¾"
22"
21-11/16"
4"
Model
Furnace casing
W arm air supply
Return air
(top)
(side)
DNS-1003
Rev. A
Blower
Maximum
Beckett
Riello
Overfire
AFUE
Blower
Motor HP /
Cooling
Burner
Burner
pressure
%
Size
Speed
at 0.25"WC
at 0.50" WC
Capacity
70 000
59 800
0.50-60W
X
81.5
Low
960
920
3.0 tons
88 200
74 600
0.50-60W
0.50-60W
81.0
Low
960
920
with high
105 000
87 800
0.60-60W
X
80.3
Med. - Low
1 100
1 000
blower
100 800
83 900
X
0.60-60W
80.3
Med. - Low
1 100
1 000
speed
119 000
97 000
0.75-70B
0.75-70B
82.2
Med. - Low
1 350
1 310
5 tons
135 800
110 000
0.85-70B
0.85-70B
81.5
Med. - Low
1 350
1 310
with high
159 600
127 000
1.00-70B
1.00-70B
80.3
Med. - High
1 605
1 510
blower speed
Model
Input
Output
Nozzle installed
Flue draft
Blower speed
Blower CFM
with filter
Ratings & Performance Direct drive units
+0.04 to +0.16
+0.10 to +0.25
10 x 10
1/2-4speeds
0.85-4speeds
+0.04 to +0.18
+0.10 to +0.25
12 x 10
Max. temp. rise
Filter quantity
Electrical load
Min. ampacity
Max. fuse size
Shipping weight
(ºF)
and size
(amps)
for wire sizing
(amps)
(pounds)
SCH-105
52 - 75
(1) 20 x 20
15.4
17.7
20
200
H-160
50 - 80
(1) 24 x 24
16.9
19.5
20
260
Model
Volt-Hertz-Phase
115- 60 -1
SC
SCH-105
SCH-160
NOTICE:
SCH furnaces are CSA design certified
for installation on combustible flooring.
Summary of Contents for SCH High Boy
Page 12: ...SCH SCL Oil Furnaces Furnace Manual 12 670 000 006 1007...
Page 13: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 13...
Page 14: ...SCH SCL Oil Furnaces Furnace Manual 14 670 000 006 1007...
Page 25: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 COMPONENTS AND REPLACEMENT PARTS 25...
Page 39: ...SCH SCL Oil Furnaces Furnace Manual 670 000 006 1007 X40132 Rev D 39...