background image

Replacement Parts List

Key No.

Description

2001621; 2031621; 2051621

2001622; 2031622; 2051622

1

Wrapper Assembly

K000275

K000275

2

Draft Diverter Assembly

K000274

K000274

3

Combustion Chamber

K000279

K000279

4

Base Plate

K000265

K000265

5

Valve Bracket

K000850

K000850

6

Control Valve

P322660

P323011

7

Burner

K000851

K000851

8

Orifice Fitting

P500086

P500086

9

Burner Orifice

P322915

P501771

10

Pilot & Generator Assembly

P501618

P501617

11

Electrode

P322276

P322276

12

Igniter Bracket

7A189

7A189

13

Vent Safety Switch

P500406

P500406

14

Thermostat

P322016

P322016

15

Wire Assembly

P500409

P500409

16

Manual Spark Igniter

P285500

P285500

17

Manifold Plate

K000852

K000852

18

Manifold Assembly

K000848

K000848

                                                         14

                                                                   2001621; 2031621; 2051621; 2001622; 2031622; 2051622 Models

Note: Screws, bolts and washers are standard hardware items and may be purchased locally.

Summary of Contents for 2001621

Page 1: ...re or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open all windows Do not try to light any appliance Do not touch any...

Page 2: ...the full value from this heater If the answer to the problem is found within this instruction manual it could help you avoid needless service costs Basic Description Helpful Installation Information T...

Page 3: ...doors so that harmful gases will not collect inside the building Follow the venting instructions for your type of installation exactly Use only the type and size of vent pipe and fittings specified 9...

Page 4: ...ay be placed directly on wood floors Heavy pile or shag rugs may restrict normal air flow Some floor coverings discolor easily from even low heat To assure safe operation a metal or wood panel extendi...

Page 5: ...on of liquefied petroleum gases WARNING WHEN CONNECTING FIELD PIPING USE A SECOND WRENCH TO KEEP THE HEATER VALVE FROM TURNING SUPPORT FIELD PIPING PROPERLY STRESS AND OVER TIGHTENING COULD DAMAGE THE...

Page 6: ...nting holes with screws provided 5 Replace the thermostat cover 6 Do not run wire in any location where it might be damaged Avoid splicing thermostat wires unless the spliced wires are properly cleane...

Page 7: ...thermostat to lowest setting 2 Turn off all electric power to the appliance if servicing is to be performed 3 Open control access panel 4 Push in gas control knob slightly and turn clockwise to OFF po...

Page 8: ...the upper left corner on the back of the heater and replace the corner bracket with the speed switch plate using the existing mounting holes item 7 The correct position for the fan switch is shown be...

Page 9: ...a horizontal run is necessary the pipe must pitch upward at least 1 4 inch to the foot It must be supported securely and joints fastened by sheet metal screws or rivets Under no circumstances should t...

Page 10: ...prevent obstructions of the vent The cowl will also prevent excessive downdraft that can cause carbon monoxide to enter into the home Do not use a homemade cowl They are dangerous and can restrict the...

Page 11: ...ed by Step 2 then input 1 000 x 3 600 34 106 000 Btu Per hour This measured input must not be greater than the input indicated on the rating plate of the heater Step 4 Relight all other appliances tur...

Page 12: ...from fan blades fan motor and exposed air passages Annually put two drops of SAE 20 oil in each of the two cups or oil tubes Pilot Burner Light pilot using instructions in OPERATING INSTRUCTIONS Leave...

Page 13: ...fficient millivoltage to open valve See 1A and 1C above E Defective valve Replace 3 Furnace operates but turns OFF before room temperature is attained A Thermostat location Check thermostat location I...

Page 14: ...or flexible chimney liner is recommended E Loose connections on the vent safety wiring harness Check the connection on both the switch and the gas valve Tighten if necessary 8 Abnormal operation A De...

Page 15: ...rifice Fitting P500086 P500086 9 Burner Orifice P322915 P501771 10 Pilot Generator Assembly P501618 P501617 11 Electrode P322276 P322276 12 Igniter Bracket 7A189 7A189 13 Vent Safety Switch P500406 P5...

Page 16: ...000079 K000079 K000041 K000041 K000045 K000045 11 Burner P501620 P501620 P501621 P501621 P501622 P501622 12 Cabinet Top K000223 K000223 K000224 K000224 K000225 K000225 13 Control Bracket K000147 K0001...

Page 17: ...16 Enclosed Front...

Page 18: ...6 P500086 P500086 P500086 13 Manifold Pipe P500087 P500087 P500088 P500088 P500089 P500089 14 Gas Control Valve P323011 P322660 P322660 P323011 P323011 P322660 15 Thermostat P322016 P322016 P322016 P3...

Page 19: ...Fireplace Look with Logs 18...

Page 20: ...e for labor or installation 3 This warranty does not extend to painted surfaces nor to damage or defects resulting from accident alteration misuse or abuse or improper installation 4 This warranty doe...