Replacement Parts List

                                                                                                        Enclosed Front

Key No.

Description

3501522 
3531522 
3551522 
3501922 
3531922 
3551922

3501521 
3531521 
3551521 
3501921 
3531921 
3551921

5001522 
5031522 
5051522 
5001922 
5031922 
5051922

5001521 
5031521 
5051521 
5001921 
5031921 
5051921

6501522 
6531522 
6551522 
6501922 
6531922 
6551922

6501521 
6531521 
6551521 
6501921 
6531921 
6551921

1

Panel Side Right

K000204

K000204

K000205

K000205

K000206

K000206

2

Thermostat

P322016

P322016

P322016

P322016

P322016

P322016

3

Inlet Duct

K7000-6022

K7000-6022

K7000-6022

K7000-6022

K7000-6022

K7000-6022

4

Bottom Louver Assembly

K000182-1

K000182-1

K000182-2

K000182-2

K000182-3

K000182-3

5

Center Panel

K000220

K000220

K000221

K000221

K000222

K000222

6

Cabinet Bottom

K5000-6003

K5000-6003

K5000-6004

K5000-6004

K5000-6019

K5000-6019

7

Panel Side Left

K000207

K000207

K000208

K000208

K000209

K000209

8

Wire Assembly

P500409

P500409

P500416

P500416

P500416

P500416

9

Top Louver Assembly

K000181

K000181

K000212-1

K000212-1

K000212-2

K000212-2

10

Combustion Chamber

K000079

K000079

K000041

K000041

K000045

K000045

11

Burner

P501620

P501620

P501621

P501621

P501622

P501622

12

Cabinet Top

K000223

K000223

K000224

K000224

K000225

K000225

13

Control Bracket

K000147

K000147

K000147

K000147

K000147

K000147

14

Orifice

P500080

P500081

P500082

P500083

P500084

P500085

15

Orifice Fitting

P500086

P500086

P500086

P500086

P500086

P500086

16

Manifold Pipe

P500087

P500087

P500088

P500088

P500089

P500089

17

Gas Control Valve

P323011

P322660

P323011

P322660

P323011

P322660

18

Electrode Igniter

P322276

P322276

P322276

P322276

P322276

P322276

19

Shield Cover

-

-

K7011-6030

K0711-6030

K0711-6031

K0711-6031

20

Pilot & Generator Assembly

P322274

P322275

P322274

P322275

P322274

P322275

21

Vent Safety Switch

P500472

P500472

P500406

P500406

P500118

P500118

22

Heat Shield (Rear)

K7003-6370

K7003-6370

K7003-6371

K7003-6371

K7003-6372

K7003-6372

23

Back Plate

K000226

K000226

K000227

K000227

K000228

K000228

24

Rear Corner Brace

K7003-6097

K7003-6097

K7003-6097

K7003-6097

K7003-6097

K7003-6097

25

Bracket

7A189

7A189

7A189

7A189

7A189

7A189

26

Manual Spark Igniter

P285500

P285500

P285500

P285500

P285500

P285500

Note: Screws, bolts and washers are standard hardware items and may be purchased locally.

                                                                                                                    15

Summary of Contents for 2001621

Page 1: ...re or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open all windows Do not try to light any appliance Do not touch any...

Page 2: ...the full value from this heater If the answer to the problem is found within this instruction manual it could help you avoid needless service costs Basic Description Helpful Installation Information T...

Page 3: ...doors so that harmful gases will not collect inside the building Follow the venting instructions for your type of installation exactly Use only the type and size of vent pipe and fittings specified 9...

Page 4: ...ay be placed directly on wood floors Heavy pile or shag rugs may restrict normal air flow Some floor coverings discolor easily from even low heat To assure safe operation a metal or wood panel extendi...

Page 5: ...on of liquefied petroleum gases WARNING WHEN CONNECTING FIELD PIPING USE A SECOND WRENCH TO KEEP THE HEATER VALVE FROM TURNING SUPPORT FIELD PIPING PROPERLY STRESS AND OVER TIGHTENING COULD DAMAGE THE...

Page 6: ...nting holes with screws provided 5 Replace the thermostat cover 6 Do not run wire in any location where it might be damaged Avoid splicing thermostat wires unless the spliced wires are properly cleane...

Page 7: ...thermostat to lowest setting 2 Turn off all electric power to the appliance if servicing is to be performed 3 Open control access panel 4 Push in gas control knob slightly and turn clockwise to OFF po...

Page 8: ...the upper left corner on the back of the heater and replace the corner bracket with the speed switch plate using the existing mounting holes item 7 The correct position for the fan switch is shown be...

Page 9: ...a horizontal run is necessary the pipe must pitch upward at least 1 4 inch to the foot It must be supported securely and joints fastened by sheet metal screws or rivets Under no circumstances should t...

Page 10: ...prevent obstructions of the vent The cowl will also prevent excessive downdraft that can cause carbon monoxide to enter into the home Do not use a homemade cowl They are dangerous and can restrict the...

Page 11: ...ed by Step 2 then input 1 000 x 3 600 34 106 000 Btu Per hour This measured input must not be greater than the input indicated on the rating plate of the heater Step 4 Relight all other appliances tur...

Page 12: ...from fan blades fan motor and exposed air passages Annually put two drops of SAE 20 oil in each of the two cups or oil tubes Pilot Burner Light pilot using instructions in OPERATING INSTRUCTIONS Leave...

Page 13: ...fficient millivoltage to open valve See 1A and 1C above E Defective valve Replace 3 Furnace operates but turns OFF before room temperature is attained A Thermostat location Check thermostat location I...

Page 14: ...or flexible chimney liner is recommended E Loose connections on the vent safety wiring harness Check the connection on both the switch and the gas valve Tighten if necessary 8 Abnormal operation A De...

Page 15: ...rifice Fitting P500086 P500086 9 Burner Orifice P322915 P501771 10 Pilot Generator Assembly P501618 P501617 11 Electrode P322276 P322276 12 Igniter Bracket 7A189 7A189 13 Vent Safety Switch P500406 P5...

Page 16: ...000079 K000079 K000041 K000041 K000045 K000045 11 Burner P501620 P501620 P501621 P501621 P501622 P501622 12 Cabinet Top K000223 K000223 K000224 K000224 K000225 K000225 13 Control Bracket K000147 K0001...

Page 17: ...16 Enclosed Front...

Page 18: ...6 P500086 P500086 P500086 13 Manifold Pipe P500087 P500087 P500088 P500088 P500089 P500089 14 Gas Control Valve P323011 P322660 P322660 P323011 P323011 P322660 15 Thermostat P322016 P322016 P322016 P3...

Page 19: ...Fireplace Look with Logs 18...

Page 20: ...e for labor or installation 3 This warranty does not extend to painted surfaces nor to damage or defects resulting from accident alteration misuse or abuse or improper installation 4 This warranty doe...

Reviews: