9  Technical data - Gas 

9.1 

Die pressure table GS 117 E / GS 152 E / 192 E 

Type 

GS 117 E 

GS 152 E 

GS 192 E 

Output 

7,12 KW 

8,12 KW 

9,18 KW 

Input (gross) 

8,0 KW 

9,1 KW 

10,2 KW 

 

Gas type 

Wobbe-

Index 

Pilot 

burner 
nozzle 

Nozzle pressure 

[mbar]  

at nominal load 

Main 

burner 
nozzle 

Nozzle pressure 

[mbar]  

at nominal load 

Main 

burner 
nozzle 

Nozzle pressure 

[mbar]  

at nominal load 

Main 

burner 
nozzle 

 

kWh/m³ 

No. 

 

No. 

 

No. 

 

No. 

Natural 

gas group 

LL 

12,4 

27 

8,8 

280 

11,2 

280 

10,1 

300 

Natural 

gas group 

15,0 

27 

8,2 

260 

10,5 

260 

7,0 

300 

Liquid gas 

(propane) 

25,7 

023 

50 

115 R 

50 

120 R3 

50 

130 R1 

9.2 

Gas flow rate table GS 117 E / GS 152 E / 192 E  

Type 

GS 117 E 

GS 152 E 

GS 192 E 

Output 

7,12 KW 

8,12 KW 

9,18 KW 

Input (gross) 

8,0 KW 

9,1 KW 

10,2 KW 

 

Gas type 

Net heating 

value HuB *) 

Gas volume [l/min.] 

at nominal load 

Gas volume [l/min.] 

at nominal load 

Gas volume [l/min.] 

at nominal load 

 

kWh/m³ 

 

 

 

Natural gas 

group LL 

8,5 

15,5 

17,6 

19,8 

Natural gas 

group E 

9,4 

14,1 

16,1 

18,0 

Liquid gas 

(propane) 

27,7 

4,8 

5,4 

6,1 

 

*Net heating value H

UB

 at gas volume at 15°C, 1013 mbar dry. 

10  Conversion kits 

GS  117  E  /  GS  152  E  /GS  192  E-  execution  with  gas  fittings  EUROSIT  630,  stainless  steel  burner  and  LOW-Energy-pilot 
burner. 

 

 

 

GS 117 E 

GS 152 E 

GS 192 E 

 

Item 

Part No 

Quantity 

Natural gas 

Group E 

Part No 

39 12 21 

39 12 21 

39 82 21 

 

Burner nozzle 

 

 

 

 

 

Ø 2,6 mm, No 260 

03 91 21 

 

Ø 3,0 mm, No 300 

03 96 32 

 

Ignition Nozzle No 27 

39 54 60 

 

Pressure regulator 

03 95 18 

Natural gas 

Group LL 

Part No 

39 92 21 

39 92 21 

39 92 22 

 

Burner nozzle 

 

 

 

 

 

Ø 2,8 mm, No 280 

03 95 32 

 

Ø 3,0 mm, No. 300 

03 97 32 

 

Ignition Nozzle No 27 

39 54 60 

 

Pressure regulator

 

03 95 18 

Liquid gas 

Group P   50 mbar 

Part No 

03 91 31 

39 83 10 

39 93 10 

 

Burner nozzle 

 

 

 

 

 

Ø 1,15 mm, No 115R 

39 13 31 

 

 

Ø 1,20 mm, No 120R3 

03 96 33 

 

 

 

Ø 1,30 mm, No 130R1 

03 97 33 

 

Ignition Nozzle No 023 

39 54 62 

 

Maximum set screw 

03 95 19 

 

Summary of Contents for GS 117 E

Page 1: ...ber who observes the local norms and regulations The installation and maintenance record must be entirely completed and the user has to be instructed accordingly Efficient operation can only be guaran...

Page 2: ...uit The tank is protected against corrosion by double coated enamel and magnesium anode An insulation layer between the internal tank and the steel plate housing minimizes loss of heat The steel plate...

Page 3: ...DN 15 b Drain pipe c Water stop valve d Manometer connection nozzle e Backflow preventer f Pressure reducing valve if more than 8 bar connection pressure g Water stop valve h Test valve i Gas stop va...

Page 4: ...min 160 205 266 Gas consumption Natural gas group E HuB 9 4 kWh m3 m3 h 0 85 0 97 1 09 Natural gas group LL HuB 8 5 kWh m3 m3 h 0 94 1 07 1 20 Liquid gas propane HuB 12 8 kWh kg kg h 0 63 0 71 0 8 No...

Page 5: ...circulation pipe must be fitted at the tank only with an original connection attachment available as spare parts at the connection point Connect the circulation pump and reverse flow stopcock between...

Page 6: ...d cuts off the gas supply automatically After a period of 5 minutes switch the gas boiler can be put again into operation see commissioning No 6ff Should the appliance cut off several times via the fl...

Page 7: ...in the tank The appliance is working automatically The gas control fittings will switch off or on the main burner depending on the water temperature At the moment the appliance is switched on again th...

Page 8: ...he measure nozzle 30 gas tight 6 Remove screw of the measure nozzle 21 and connect U tube manometer 7 Open gas stop cock and put appliance into operation according to Commissioning page 7 8 Check that...

Page 9: ...ypes Any conversion is only to be undertaken by a registered specialist 8 1 From natural gas to liquid gas 8 1 1 Close gas stop cock and remove cover plate 15 8 1 2 Remove burner unit Loosen screws fo...

Page 10: ...l min at nominal load Gas volume l min at nominal load kWh m Natural gas group LL 8 5 15 5 17 6 19 8 Natural gas group E 9 4 14 1 16 1 18 0 Liquid gas propane 27 7 4 8 5 4 6 1 Net heating value HUB at...

Page 11: ...ormed of the importance of regular maintenance and that this is a decisive factor as to how long the appliance will last Openings necessary to allow air circulation around the site of installation mus...

Page 12: ...ked I Check gas supply adjust dimensions of gas pipes clean connecting pipes clean dirt filter Ignition nozzle blocked I Clean ignition nozzle The installed ignition nozzle is too small I Install corr...

Page 13: ...e has been modified through the installation of externally supplied parts or through irregular professional maintenance Subject to our general terms and conditions Legal warranty 2 years Guarantee yea...

Page 14: ...aller Signature Signature Place of installation Name ZIP Code Place Street Phone Tank model Serial number Date of invoice Anode maintenance record Date Visual examination of anode Exchange of anode Si...

Reviews: