Deck oven
Check the device/combined installation for obvious faults before installation.
A defective appliance must not be put into operation.
Position the combined installation at its location.
Observe the minimum distances according to the individual installation plan.
1100 mm
1800 mm
HAZARD
Electrical contact!
Danger of electrocu-
tion!
Electrical connection of the device may only be carried out
by an electrician according to electrical industry rules. Electri-
cal fuse protection of the plug socket must be provided with
a fault-circuit current-breaker.
Observe guidelines from the VDE and the local power companies.
3.6.1. Electrical connection
3.6. Connection
The electrical connections must be made within the speci-
fi ed installation window, but not below the water connection
(see Water connection).
Electrical fuse protection of the plug sockets must be provided
with a fault current circuit breaker.
Every mains plug has to also be accessible after the installa-
tion. If this is not possible, a mains switch must be provided by
the customer.
This main switch must be specifi cally assigned to the con-
nected units and be obvious to the user.
Use a separate fuse-protected supply cable for each appli-
ance.
The cross-sections of the connection lines conform with the
power consumption and the local conditions.
3.6.1.1. Connecting via a power generator
The power generator must be designed for the total power of the device. For installations, the power
generator must be designed for the total connected load of the combined installation.
Mains type:
400V 3/N/PE 50/60 Hz
Stability:
with load change (total output on-off switching)
The voltage should not differ by more than +/- 10 %
The frequency should not differ by more than +/- 2 %
Electrical connection installation window