Applications
60
© 2010 Wieland Electric GmbH | BA000256 | 12/2012 (Rev. I)
When the safety door monitored with
MS1
is opened
K1
and
K2
shut down. When the
safety door monitored with
MS2
is opened
K3
and
K4
shut down.
In case of emergency stop via
S1
, all contactors
K1
to
K2
shut down. With button
S2
you can reset the safety system while the safety devices are closed. Reset button
S2
is
monitored for errors.
samos
module
K6
K6A
Type
SA-BM-S1
SA-IN-S1
FUNCTION
8
4
4
Function group
AB
A
B
A
B
External circuitry category (EN ISO 13849-1)
up to
3
3
4
4
Cross-circuit monitoring
–
–
X
X
Synchronous time monitoring
–
–
–
–
Stop category (EN 60204-1)
0
0
OFF delay
Q4
0 s
Retriggering ON
–
AUTO-RESET after POWER ON
MANUAL RESET after POWER ON
X
X
AUTO-RESET
MANUAL RESET
X
X
Comment
samos
modules and contactors in the same enclosure
Application example
A 258_B
Two independent safety
zones
Monitoring with coded
electromagnetic
switches
Higher-order emergency
stop
Category 3/4
Stop category 0
+ Combination
of fl AND
operation
SA-IN-S1
Summary of Contents for samos
Page 76: ......