SA-BM Base Module
28
© 2010 Wieland Electric GmbH | BA000256 | 12/2012 (Rev. I)
Function blocks
FUNCTION
Function
group
Application e.g.
Switch position not allowed
Emergency stop, safety door, 4-wire switching mat
Dual-channel NC/NC with cross monitoring, stop category 0
OR
Safety door monitoring with electromagnetic switches,
valve
position
monitoring
Dual-channel NC/NO with cross monitoring, stop category 0 and 1
OR
3.1* Non-contact safety device type 4, emergency stop, safety door
Dual-channel NC/NC, single-channel NC, stop category 0 and 1
3.2* PDF, Stop category 0 and 1
Non-contact
safety device type 2, Stop category 0 and 1
Muting
Two-hand function EN 574 Type IIIC, safety door
2x dual-channel NC/NO with cross monitoring
Emergency stop, safety door
Dual-channel NC/NC with cross monitoring
5.1* Two-hand function EN 574 Type IIIA
NO/NO with cross monitoring
5.2* Jog mode with 5 s operating time restriction
NO/NO with cross monitoring
Emergency stop, safety door
Dual-channel NC / NC with cross monitoring, stop category 0 and 1
Emergency stop, safety door
Dual-channel NC / NC with cross monitoring, stop category 0 and 1
Emergency stop, safety door, non-contact safety device type 4
Dual-channel NC/NC, single-channel NC, stop category 0 and 1
Emergency stop, safety door, non-contact safety device type 4
Dual-channel NC/NC, single-channel NC, stop category 0 and 1
Emergency stop, safety door, non-contact safety device type 4
Dual-channel NC/NC, single-channel NC, stop category 0
Emergency stop, safety door, non-contact safety device type 4
Dual-channel NC/NC, single-channel NC, stop category 0 and 1
Emergency stop, safety door
Dual-channel NC / NC with cross monitoring, stop category 0 and 1
Emergency stop, safety door, non-contact safety device type 4
Dual-channel NC/NC, single-channel NC, stop category 0 and 1
* For special functions