5.8
Wieland Electric | BA000349 | 05.2007
Commissioning
| 5
The "Parameter Setting" tab displays the parameters for the DP slave
The parameter names and the default setting of the values are defined in the GSD file for
the DP slave.
Explanations for the individual parameters can be found in the manual for the DP slave.
This DP slave features the following behavior:
• No alarms can be planned at the slave.
• In the SFB54, the slave is reported as DPV0 slave.
• Diagnostic events lead to the call of OB82
The parameter setting data are listed in hex format under the "Hex Parameter Setting" folder. A
prerequisite for adjusting the values is that you are familiar with the structure of the parameter
setting frame of the DP slave (see also EN 50170 or IEC 61158).
Hex parameter
setting
Hex parameter
setting
"Parameter Set-
ting" tab
Summary of Contents for podis MOT FP C